Chapter 1
Ready, set up, go
11
CONNECTIONS
Ducting version air exhaust system
When installing the hood in ducting version, a rigid or a flexible pipe with the diameter corresponding
to the flange diameter is used in order to connect the hood to the air outlet piping.
• Fix the pipe with an adequate quantity of pipe clamps (not supplied).
• Remove possible charcoal filters.
Recirculation version air outlet
• Cut a hole ø 125 mm in any shelf that may be positioned over the hood.
• Insert the flange 10a on the hood body outlet.
• Connect the flange to the outlet on the shelf over the hood using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps (not supplied).
• Fix the directional grille 8 on the recirculation air outlet using the 2 screws 12e
(2,9 x 12,7) provided.
• Ensure that the activated charcoal filters have been inserted.
Electrical connection
Connect the hood to the mains through a two-pole switch having a contact gap of at least 3mm.
12e
8