InstallatIon
Installation must be carried out in compliance with current standards and
regulations.
Installation must only be carried out be a licensed electrician in accordance with the
latest wiring rules AS/NZS 3000.
Cabinet requirements
For fitted units, the components (plastic materials and veneered wood) must be
assembled with heat-resistant adhesives (min. 100°C): Unsuitable materials and
adhesives can result in warping and detachment.
The cabinet for the oven must allow sufficient room for the electrical connections of
the oven.
The cabinet for the oven must be sturdy enough to withstand the weight of the oven.
The oven must be securely installed in the recess. The oven can be installed in a
column housing unit or below the countertop of a modular unit, provided sufficient
ventilation is guaranteed.
Electrical connection
Franke ovens are supplied with a power cable.
Installation must only be carried out by a licensed electrician in accordance with the
latest wiring rules AS/NZS 3000
–
In this case the connection
polarities
of the free terminals are
as follows:
Brown = Line
Blue = Neutral
Yellow / Green = Earth
blue
yellow/green
brown
X
X
Make sure the characteristics of the household electrical system (voltage,
maximum power and current) are compatible with those of the oven.
If the oven is to be permanently connected to the power supply:
X
X
Install a device that enables disconnection from the power supply, with a contact
opening distance (3 mm) that ensures complete disconnection in category III
overvoltage conditions.
Three free terminals ( a three-pole power cable with free terminals) Fig.3b
XX
The means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
FS 913 P BK DCT TFT AUS