Franke FilterFlow mini Installation Manual & Technical Information Download Page 3

SeCtIon 2: 

ImPoRtant tHInGS to ConSIDeR

water Supply (water Fittings) Regulations 1999

Familiarise yourself with the requirements of the Water Supply 
Regulations 1999: www.legislation.gov.uk/uksi/1999/1148/
contents/made

maximum working Pressure 6 bar/90psi

Measure the pressure during the ‘low demand’ period, when 
the pressure will be at its highest e.g. mid-morning, mid-after-
noon or late evening.  If the pressure exceeds 6 bar/90psi, it 
will be necessary to install a suitable pressure reducing valve 
in the supply line upstream of the filter stop valve. (A suitable 
pressure reducing valve is available online  
at www.FrankeFilterFlow.co.uk/)

minimum Pressure 1.5 bar/23psi 

This is the minimum pressure recommended to achieve an 
acceptable flow.

Filter Housing

The filter housing is precision engineered in ABS plastic and 
will require no routine maintenance beyond regular lubrication 
of the large sump ‘O’ Seal (see Lubrication below) and an 
occasional wipe with a damp cloth. 

Important. 

Under no circumstances should the housing come 

in to contact with household cleaners as this may cause the 
housing to fracture. Do not install the housing where it is 
permanently exposed to daylight, as over time extended 
exposure will degrade the plastic.  As a precaution the housing 
should be replaced every 10 years. 

taking care of the green flexible tubing

Although the tube can withstand significant water pressure do 
not stretch , kink or expose the green plastic tubing to a naked 
flame during installation.  Do not allow the tube to come in to 
contact with solvents and proprietary cleaners.

lubrication

Applying a smear of grease to the large ‘O’ seal on the head of 
the housing at each cartridge change will ensure the two parts 
of the filter housing are easy to separate and re-assemble.  

I

mportant.

 Use only WRAS (Water Research Advisory Service) 

approved silicon grease to lubricate the rubber seals, as rubber 
and plastic parts will degrade and eventually fail if the wrong 
grease is used. A suitable grade of silicon grease is available to 
purchase online at www.FrankeFilterFlow.co.uk 

Periods away from home 

If you are planning to leave the premises where the filter is installed 
for an extended period it is advisable to isolate the filter system. 
Turn off the water supply to the filter using the filter stop valve. Turn 
the filtered water tap on and off a few times to release the pressure 
in the system. When you return just turn the water supply back on 
and run the water for a few minutes before use. 

SeCtIon 3: 

PlannInG YouR InStallatIon

Although your Franke FilterFlow system is designed for ease of 
installation, careful planning and preparation before commenc-
ing the installation will ensure the procedure is straightforward 
and trouble-free. 

Choosing the location 

Choose the most convenient place to tee into the 15mm cold 
water supply to install the stop valve. Decide the best place to 
position the filter unit within the kitchen cabinet. Bear in mind 
the need for easy access to make future filter cartridge chang-
es a simple process. Ensure the braided flexible hose and the 
flexible plastic tube can be fitted without stretching or 
kinking.  

Installing the Filter System above the Ground Floor

Extra care should be taken when installing water appliances 
above the ground floor. To reduce the risk of potentially 
catastrophic flooding, install an automatic shut-off device at 
the outlet of the filter stop valve.

backflow Prevention

To comply with UK Water Supply (Water Fittings) Regulations 
1999, a suitable check valve (non-return valve) arrangement 
should be installed upstream of the filter stop valve. 

Plumbing Connections

The stop valve supplied with the system is for connection to 
15mm copper pipework. For alternative connection options 
please contact Franke FilterFlow customer service. 

3

Summary of Contents for FilterFlow mini

Page 1: ...franke filTerflow mini carTriDge housing Installation Guide technical Information Please retain for future reference Franke FilterFlow mini typical installation...

Page 2: ...and in the future Section 1 How the System Operates The Franke FRF02 multi stage water filter cartridge supplied as standard with your FilterFlow mini system is capable of removing a wide range of po...

Page 3: ...S Water Research Advisory Service approved silicon grease to lubricate the rubber seals as rubber and plastic parts will degrade and eventually fail if the wrong grease is used A suitable grade of sil...

Page 4: ...ng their heads protruding approximately 3mm to allow the bracket D to be easily lifted on and off the screws Note Depending on the nature of the cabinet it may be necessary to position a batten behind...

Page 5: ...the connector Fit the male stem of the push fit connector elbow into the outlet of the filter housing head and push it fully home Important note making the push fit connections Make sure that the tube...

Page 6: ...contami nants This often occurs soon after a new system is installed due to plumbing residues solder fluxes etc becoming trapped on the surface of the filter cartridge If this happens inside the reco...

Page 7: ...the assembled housing on the two retaining screws 3 Have a bowl to hand Grip the sump firmly and turn it to the left just sufficient to break the seal Lift the filter housing assembly off its two supp...

Page 8: ...ligent use or care misuse neglect careless operation or handling of the filter system which is not in accordance with the Franke FilterFlow operating guidlines Use of the filter system for anything ot...

Reviews: