16
After fitting the injectors, use soap to check for gas leakage. To do this, apply suds
to the bottom side of the injectors.
Put your finger on the injector to block the gas outlet and check if there are
bubbles on the connection point of the injector.
Technical data
Technical Information About Gas Burners
(G20-20 mbar) - (G30-30 mbar) (G30-37mbar)
Burner A
1 kW
Burner SR
1.75 kW
Burner R
3 kW
Wok Burner
(2.5 kW)
Ø 100
Wok Burner
(3.3 kW)
Ø 100
Wok Burner
(3.8 kW)
Ø 126
G30-30
Mbar LPG
(0.50 mm)
G30-30
Mbar LPG
(0.65 mm)
G30-30
Mbar LPG
(0.85 mm)
G30-30
Mbar LPG
(0.82 mm)
G30-30
Mbar LPG
(0.89 mm)
G30-30
Mbar LPG
(0.98 mm)
G20-20
Mbar NG
(0.72 mm)
G20-20
Mbar NG
(0.97 mm)
G20-20
Mbar NG
(1.15 mm)
G20-20
Mbar NG
(1.15 mm)
G20-20
Mbar NG
(1.28 mm)
G20-20
Mbar NG
(1.35 mm)
G30-37
Mbar LPG
(0.47 mm)
G30-37
Mbar LPG
(0.62 mm)
G30-37
Mbar LPG
(0.80 mm)
G30-37
Mbar LPG
(0.93 mm)
1. Nitrile/Cylinder head seal
2. Elbow
3. LPG hose inlet
When performing natural gas-LPG conversion, please use the LPG hose inlet shown
in the figure to complete the conversion.
Summary of Contents for FHNG 302 2G BK C
Page 2: ...2...
Page 20: ...20 Figura 3 30 VETRO 30 ACCIAIO INOX 70 ACCIAIO INOX 70 VETRO 60 VETRO 60 ACCIAIO INOX...
Page 33: ...2...
Page 51: ...11 Figure 3 30 GLASS 30 INOX 70 INOX 70 GLASS 60 GLASS 60 INOX...
Page 64: ...2...
Page 83: ...21 Figure 3 30 VERRE 30 INOX 70 INOX 70 VERRE 60 VERRE 60 INOX...
Page 96: ...2...
Page 114: ...20 Figura 2 30 CRISTAL 30 INOXIDABLE 60 CRISTAL 60 INOXIDABLE...