![background image](http://html1.mh-extra.com/html/franke/fgc-915-i-xs-led/fgc-915-i-xs-led_instructions-for-use-and-installation_2327982008.webp)
EN
8
8
Air outlet – Recirculation Version
• Insert the Connector extensions 14.1 into the side of the Con-
nector 15.
• Insert the Connector 15 into the Support bracket 7.1 and fix it
with the screws.
• Fasten the Support bracket 7.1, fixing it to the upper part with
the Screws.
• Make sure that the Connector extensions outlet 14.1 is in cor-
respondence with the Chimney openings both horizontally and
vertically.
• Join the Connector 15 to the Hood canopy outlet using a rigid
or flexible pipe ø¸150 mm, selection of which is at the discre-
tion of the installation technician.
• Make sure that the Activated charcoal odour filter has been
fitted.
7.1
7.1
12c
12e
15
14.1
Application of Novastick Tape
• Apply the Novastick tape 16 to the front edge of the Upper
Chimney from the top part down to the start of the Lower
Chimney.