MAINTENANCE

 

Opening Panel 

•  Open the Panel by pulling it. 
•  Clean the outside with a damp cloth and neutral detergent. 
•  Clean the inside using a damp cloth and neutral detergent; do 

not use wet cloths or sponges, or jets of water; do not use 
abrasive substances. 

 

Metal grease filters 

They can be washed in the dishwasher, and need to be cleaned 
whenever the 

FG

 sign appears on the display or at least once 

every 2 months use, or more frequently if use is particularly 
intensive. 

Resetting the alarm signal 

•  Turn the Lights and the Suction motor off, then disable the 24h 

function, if enabled. 

• Press button 

E

 (see the paragraph on Use). 

Cleaning the Filters 

•  Open the Comfort panels by pulling on the recess. 
•  Remove the Filters one at a time, pushing them towards the 

back of the unit and at the same time pulling downward. 

•  Wash the Filters without bending them, and leave them to dry 

completely before replacing. (If the surface of the filter 
changes colour as time goes by, this will have absolutely no 
effect on the efficiency of the filter itself.)  

•  Replace, taking care to ensure that the handle faces forwards. 
•  Close the Comfort panels. 
 

 

Summary of Contents for FGB 906 W AC

Page 1: ...lation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullan m ve montaj talimatlar Davlum...

Page 2: ...CHE 13 INSTALLAZIONE 14 USO 17 MANUTENZIONE 19 SOMMAIRE CONSEILS ET SUGGESTIONS 21 CARACTERISTIQUES 22 INSTALLATION 23 UTILISATION 26 ENTRETIEN 28 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 30 CHARA...

Page 3: ...lationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticus...

Page 4: ...pper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 50 1 Control Board Group Ref Q ty Installation Components 7 2 1 2 Upper...

Page 5: ...chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical refe...

Page 6: ...lexible or rigid pipe 150 or 120 mm the choice of which is left to the installer To install a 120 mm air exhaust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in positio...

Page 7: ...xhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9...

Page 8: ...nds These indications are only visible when the motor is turned off FF flashes three times When the procedure terminates the indication shown previously turns off FG indicates the need to wash the met...

Page 9: ...ure Activates Deactivates the Intensive function Anti condensatio n Long pressure Activates Deactivates the Anti condensation heating elements 24H Delay Brief pressure Activates Deactivates the Delay...

Page 10: ...larly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button E see the paragraph on Use Cleaning the Filters Open the Comf...

Page 11: ...alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button E see the paragraph...

Page 12: ...991 0350 632_ver4 Franke S p a Via Pignolini 2 37019 Peschiera del Garda VR www franke it...

Reviews: