Franke FFPD100 SERIES Installation Manual Download Page 8

8

ENGLISH

Limited lifetime warranty

Franke Consumer Products, Inc., Kitchen Systems Division extends the following warranty to the origi

-

nal purchaser of its faucets effective January 1, 2003. 

All  faucets  installed  in  a  private  residence  will  carry  a 

limited  lifetime  warranty 

on  all  mechanical 

parts to be free of manufacturing defects in material and workmanship under normal usage. 

All chrome 

finishes carry a limited lifetime warranty; all other finishes are warranted for five (5) years form the 

original date of purchase.

Marine and Outdoor Installation

: Franke Consumer Products, Inc. faucets are NOT warranted for 

Marine and Outdoor installations.

This warranty applies only to the original owner, providing the product has been installed in accordance 

with our installation instructions, used as recommended and in a normal residential application. 

In the 

event of a warranty claim, the owner will be required to provide proof of purchase - save sales 

receipt

. This warranty covers all components which make the product operational. Franke, at its op

-

tion, may repair or replace the product or components necessary to restore the product to good working 

condition. Franke reserves the right to inspect the installation 

prior 

to the actual replacement of the 

product or component part.

This warranty does not cover misuse or abuse, accidental damages, scuffs or scratches, improper installa

-

tion, abnormal usage, negligence or damage caused by improper maintenance or cleaning. Normal wear 

of parts is excluded from the warranty. Damage caused by impurities or acts beyond our control are not 

covered. Any product or part which has been repaired or altered in any manner outside of Franke’s fac

-

tory, unless previously authorized in writing by Franke, will void warranty. 

Any replacement excludes 

transportation and any labor re-installation costs

. This warranty does not allow recovery of incidental 

or consequential damages such as loss of use, delay, property damage or other consequential damage, 

and Franke accepts no liability for such damages.

The Franke warranty is limited to the above conditions and to the warranty period specified herein and is 

exclusive. Franke DISCLAIMS all other warranties, expressed or implied, including IMPLIED WAR

-

RANTIES OF MERCHANTABILITY AND/OR FITNESS FOR AS PARTICULAR PURPOSE. This 

warranty gives you specific legal rights that may vary from state to state.

Further information

For any further information about our products, about the installation

of them or about the guarantee, please dial the number of the

customer service:

Phone 1-215-822-6590

Or: 1-800-626-5771

Fax 1-215-822-5873

Franke Consumer Products Inc. - Kitchen Systems Division

3050 Campus Drive, Suite 500 Hatfield, PA 19440

Summary of Contents for FFPD100 SERIES

Page 1: ...FFPD100 SERIES Swivelling spout faucet with spray head Installation guide ...

Page 2: ...EATURES Maximum water flow 2 2 gpm 60 psi Recommended pressure range 15 75 psi Over 75 psi PRV required Complies with Proposition 65 NSF61 UPC and C UPC requirements TECHNICAL DATA Minimum working pressure 0 5 bar Maximum working pressure 5 bar Recommended working pressure 3 bar in case of water pressure higher than 5 bar it is recommended to install pressure reducers Maximum working temperature 7...

Page 3: ...zed table and picture NOTE Call us immediately if you see inconsistencies 1 800 626 5771 or visit www frankeksd com TABLE OF CONTENTS 1 Faucet 2 Wall fastening set 3 Wall flange over the sink 4 Wall flange under the sink 5 Fastening set rubber washer triangular flange metal washer nut 6 Non return valves 3 1 2 4 5 6 ...

Page 4: ... return valve with the gaskets as indicated in the figure NOTE solid surface installation The sub countertop mounting surface needs to be flat and free of debris otherwise the faucet will not sit properly Tile installation Avoid installations near or on top of grout lines The faucet will not sit secure when sitting on such 2 Remove all mounting hardware from protecting plastic bag 3 Place the larg...

Page 5: ... the cabinet 7 The body can be fixed both onto the wall and on surface 1 Screw the fixing rail onto the single lever body 2 Insert it completely in the given plate 3 Place the single lever body into the sink hole made at a certain distance from the wall 4 Place the plate properly where it has to be fixed making sure the drilling points on the wall are well marked corresponding to the two holes wit...

Page 6: ...cet handle to the OFF position 4 Use a the provided allen key to loosen the set screw which is accessible from the back of the handle 5 Lift the handle from the cartridge 6 Find the small notch at the base of the chrome ring cap and carefully pry up against this to remove the cap 7 Remove the brass retaining ring 8 Lift out the cartridge 9 Ensure that the seats and O rings are in good condition 10...

Page 7: ... the handle from the headvalve 6 Unscrew then the headvalve using a 17 mm wrench and replace it 7 Reinstall all the details proceeding in opposite order 2 mm 1 16 key 17 mm 11 16 key General maintenance Clean aerator periodically Do not use harsh detergents solvents chemical agents metallic sponges etc that could harm the surface Clean only with a soft sponge and soapy water Clean and then dry pro...

Page 8: ...or component part This warranty does not cover misuse or abuse accidental damages scuffs or scratches improper installa tion abnormal usage negligence or damage caused by improper maintenance or cleaning Normal wear of parts is excluded from the warranty Damage caused by impurities or acts beyond our control are not covered Any product or part which has been repaired or altered in any manner outsi...

Reviews: