![background image](http://html1.mh-extra.com/html/franke/ffc-1005-xs-led0/ffc-1005-xs-led0_instructions-for-use-and-installation_2327974010.webp)
EN
1
10
Mounting the hood body
• If, according to installer, the empty space between the lower
part of the hood and the wall corner has to be filled, it is then
necessary to install the corner spacer
7.1
at the hood basis us-
ing two screws
12c
(2,9 x 9,5) supplied.
• Fasten the two screws
Vr
placed at the hook areas of the hood.
• Hang the hood body on the specific screws
12b
(4,2 x 12,7).
• Fasten definitively the support screws
12b
(4,2 x 12,7).
• It is possible to level the hood body by adjusting the screws
Vr
.
• To definitively fix the hood to the ceiling it is necessary to use
two remaining screws together with plug and washer. These
have to be placed from inside the hood.
12b
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the reduc-
er flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
ø 150
9
ø 120
RECIRCULATION VERSION AIR OUTLET
• Insert the extension pieces
14.1
laterally on the air outlet con-
nection piece
15.
Fix the connection piece with the extension pieces onto the
support
7.3
using the two screws
12c
(2,9 x 9,5) provided.
• Insert the assembled unit inside the upper chimney support
7.4
using the 4 screws
12c
(2,9 x 9,5) provided.
• Connect the hood with the air outlet connection piece using a
rigid or a flexible ø150 tube chosen by the installer. It will be
necessary to use narrow strips (not provided) for this connec-
tion.
• Make sure that the charcoal filter has been mounted inside the
hood.
12c
12c
Summary of Contents for FFC 1005 XS LED0
Page 8: ...EN 8 8 Dimensions...
Page 18: ...IT 1 18 Ingombro...
Page 28: ...FR 2 28 Encombrement...
Page 38: ...DE 3 38 Platzbedarf...
Page 48: ...TR 4 48 Boyutlar...
Page 58: ...CZ 5 58 Prostorov rozm r...
Page 68: ...FI 6 68 Mitat...
Page 74: ...UA 7 74 650 I 120 0 04 2...
Page 75: ...UA 7 75 3 8...
Page 76: ...UA 7 76 2 4...
Page 78: ...UA 7 78...
Page 81: ...UA 8 81 3 7 4 12 2 9 x 9 5 12c 2 9 x 9 5 12c 12c...
Page 82: ...UA 8 82 T1 T2 1 T3 2 Delay 2 30 Intensive T4 3 Intensive 6 Delay L...
Page 83: ...UA 8 83 2 4...
Page 88: ...RO 8 88 Dimensiuni...
Page 94: ...SA 9 94 650 I 120 0 04 2...
Page 95: ...SA 9 95 3 8...
Page 96: ...2 4 SA 96...
Page 98: ...SA 9 98...
Page 101: ...SA 1 101 7 4 2 12c 2 9 x 9 5 2 12c 2 9 x 9 5 12c 12c...
Page 102: ...SA 1 102 T1 T2 T3 2 Delay 30 T4 6 L...
Page 103: ...SA 1 103 4...