background image

 

 

 

 

 

EN 

1

17 

Mounting the hood body 

•  Screw the two screws 

12d

 supplied onto the brackets 

7.1

•  Hook the hood body onto the bracket 

7.1, 

centring it around 

the vertical line. 

•  Use the adjusting screws 

12d

 underneath the hood to level the 

hood body. 

 

12.d

7.1

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to the 
chimney using either a flexible or rigid pipe ø 150 or 120 mm, 
the choice of which is left to the installer. 
•  To install a ø 120 mm air exhaust connection, insert the re-

ducer flange 

9

 on the hood body outlet. 

•  Fix the pipe in position using sufficient pipe clamps (not sup-

plied). 

•  Remove any activated charcoal filters. 

 

ø 120

ø 150

9

RECIRCULATION VERSION AIR OUTLET 

•  Push fit the air outlet fitting 

15

 onto the air outlet of the hood 

body. 

 
•   Ensure that the activated charcoal filters have been inserted. 

 

15

Summary of Contents for FDS 654

Page 1: ...zione Cappa Instructions for use and installation Cooker Hood Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullan m ve montaj talimatlar Davlumba...

Page 2: ...EN 3 3 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 14 CHARACTERISTICS 15 INSTALLATION 16 USE 19 MAINTENANCE 20...

Page 3: ...f aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of c...

Page 4: ...2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 2 Hood Body Fixing Brackets 7 2...

Page 5: ...centres of the holes in the bracket Place bracket 7 1 as shown 110 mm from the vertical reference line and 180 mm above the horizontal reference line Mark the centres of the holes in the bracket Repe...

Page 6: ...version connect the hood to the chimney using either a flexible or rigid pipe 150 or 120 mm the choice of which is left to the installer To install a 120 mm air exhaust connection insert the re ducer...

Page 7: ...Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using th...

Page 8: ...n and off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum treate...

Page 9: ...ake sure that the han dle is visible on the outside Activated charcoal filter Recirculation version These filters are not washable and cannot be regener ated and must be replaced approximately every 4...

Page 10: ...iel lectrique et lectronique En vous assurant que ce produit est limin correctement vous favorisez la pr vention des cons quences n gatives pour l environnement et la sant humaine qui sinon seraient l...