background image

 

 

 

 

EN 

 

1

1

 

11 

INSTALLATION

 

The cooker hood must be installed centrally over a cooking appliance. The minimum distance 
between the cooking surface and the metal grease filters on the underside of the hood must be 
at least 650mm. 
To install the hood proceed as follows: 
1)   Drill six 8mm diameter holes at 

X1-X2-J

 and insert the plastic rawl plugs supplied as illus-

trated in fig. 2 ensuring the brackets are fitted as shown in the blow up.   

2)   Secure the two brackets 

C

 to the wall inserting two of the screws supplied through the two 

holes on line 

X1-X2

 as illustrated in fig. 2. 

3)   Slide the canopy down the wall to locate the key hole over the washer then secure the can-

opy to the wall by inserting two of the screws supplied through the two outer holes in the 
rim of the canopy 

J1

 and 

J2

 as illustrated in fig. 3.  

4)  

EXTRACTION OR RECIRCULATION INSTALLATION: 

•  EXTRACTION (DUCTED) 

When installing the ducted version, connect the hood to the chimney using either a flexible or 
rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. 
•    To install a ø 120 mm air exhaust connection, insert the reducer flange 

9

 on the hood body 

outlet. 

•    Fix the pipe in position using sufficient pipe clamps (not supplied). 
•    Remove any activated charcoal filters. 

•  RECIRCULATION (FILTERED) 

•    When the hood is fitted in the recirculation mode the Air Outlet Connection 

H

 should be 

fitted as illustrated in fig. 6. 

•    Fit the (optional) charcoal filters by repeating the following operation on each side of the 

motor housing. Place the two key hole slots in the filter 

L

 and turn the filter clockwise to 

lock the filter in position as illustrated in fig. 7.  
WARNING: It is a possible fire hazard if the metal grease filters are not cleaned and the 
charcoal filters replaced regularly. 

Fitting The Chimney 

5)   FITTING THE CHIMNEY UPPER 
    To fit the upper chimney 

A

, place the top edge of the chimney over the bracket 

C

 as illus-

trated  in  fig.  8  and  secure  the  chimney  using  two  of  the  2.9mm  self  tapping  screws  pro-
vided. 

    The  distance 

H

  in  the  height  between  the  fixing  holes 

X1

  and 

X2

  is  determined  by  the 

height of the upper chimney 

A

.  

6)   FITTING THE CHIMNEY LOWER 
    To fit the lower chimney 

B

, apply slight force to the two rear edges to increase the width 

of the apperture, then sleeve the chimney 

B

 over the chimney 

A

 as illustrated in fig. 9. 

 

 
 