RECOMMENDATIONS AND SUGGESTIONS

 

  The Instructions for Use apply to several versions of this appliance. Accord-

ingly, you may find descriptions of individual features that do not apply to 
your specific appliance. 

INSTALLATION 

•  The manufacturer will not be held liable for any damages resulting from incor-

rect or improper installation. 

•  Check that the main voltage corresponds to that indicated on the rating plate 

fixed to the inside of the hood. 

•  The electrical supply must be properly and sufficiently grounded. 
  Connect the extractor to the exhaust flue through a pipe of minimum diameter 

6”. The route of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion fumes 

(boilers, fireplaces, etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas 

burning appliances), a sufficient degree of aeration must be guaranteed in the 
room in order to prevent the backflow of exhaust gas. The kitchen must have 
an opening communicating directly with the open air in order to guarantee the 
entry of clean air. 

 

 

USE 

•  The range hood has been designed exclusively for domestic use to eliminate 

kitchen odors. 

•  Never use the hood for purposes other than for which it has ben designed. 
•  Never leave high naked flames under the hood when it is in operation. 
•  Adjust the flame intensity to direct it onto the bottom of the pan only, making 

sure that it does not engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil can 

burst into flames. 

•  The hood should not be used by children or persons not instructed in its cor-

rect use.  

 

CARE 

•  Switch off or unplug the appliance from the main supply before carrying out 

any maintenance work. 

•  Clean and/or replace the Filters after the specified time period. 
•  Clean the hood using a damp cloth and a neutral liquid detergent.. 

 

 

 

Summary of Contents for FDL 304 W

Page 1: ...PRESTIGE 30 PRESTIGE 36 Range Hood Hotte Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien FDL 304 W FDL 364 W...

Page 2: ...EN 2 2 INDEX WARNINGS AND REQUIREMENTS 3 RECOMMENDATIONS AND SUGGESTIONS 6 DIMENSIONS and MAIN PARTS 7 INSTALLATION 8 USE 11 CARE 12...

Page 3: ...WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consu...

Page 4: ...exible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the ap pliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at ea...

Page 5: ...When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors W A R N I N G Electrical ground is required o...

Page 6: ...as burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the op...

Page 7: ...10 1 Damper 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 2 Hood Body Fixing Brackets 7 2 1 1 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 11 8 Wall Plu...

Page 8: ...ket 7 1 as shown 4 5 16 from the vertical reference line and 7 1 2 above the horizontal reference line Mark the centres of the holes in the bracket Repeat this operation on the other side REAR PANEL O...

Page 9: ...e the necessary structure and support for mounting 12 d 7 1 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using a rigid 6 duct Instal...

Page 10: ...ngehood with a twist on type wire connector Replace the cover Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper flue and hook them behind the brackets 7 3 and 7 2 1 maki...

Page 11: ...tor Switches the extractor motor on and off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating c...

Page 12: ...handle of the filter remain outside Activated charcoal filter Ductless version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation...

Page 13: ...14 FR 1 4 13 TABLE DES MATI RES AVERTISSEMENT ET CONDITIONS N CESSAIRES 14 CONSEILS ET SUGGESTIONS 17 DIMENSIONS et PRINCIPALES PI CES 18 INSTALLATION 19 UTILISATION 22 SOIN ET ENTRETIEN 23...

Page 14: ...contre le feu N utilisez un extincteur que si 1 Vous avez sous la main un mod le ABC et vous comment l utiliser correctement 2 Le feu est faible et peu r pandu 3 Les pompiers sont d j pr venus 4 Vous...

Page 15: ...diaire de c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un serre c ble de po 12 7 mm homologation UL ou CSA doit tre install chaque extr mit du c ble d alimentation...

Page 16: ...t l American Society for Heating Refrigeration and Air Condition Engineers ASHRAE ainsi que les codes municipaux Lors d op ration de d coupage et de per age dans un mur ou un plafond veiller ne pas en...

Page 17: ...la pi ce ou est install e la hotte par exemple des appareils fonctionnant au gaz vous devez pr voir une a ration suffisante de l espace Si la cuisine en est d pourvue pratiquez une ouverture qui commu...

Page 18: ...inf rieure 10 1 Clapet anti reflux 15 1 Raccord de sortie d air Ref Qt Pi ces servant l installation 7 1 2 Brides de montage de la hotte 7 2 1 1 Brides de montage de la chemin e sup rieure 7 3 1 Bride...

Page 19: ...centres des trous du support Placer le support 7 1 comme indiqu 4 po 5 16 de la ligne verticale de r f rence et 7 po 1 2 au dessus de la ligne horizontale de r f rence Marquer les centres des trous d...

Page 20: ...ture requise et le sup port de montage 12 d 7 1 Branchements SORTIE D AIR VERSION ASPIRANTE En cas d installation en version aspirante brancher la hotte la tuyauterie de sortie via un tube rigide de 6...

Page 21: ...le Montage de la chemin e Chemin e d chappement sup rieure largir l g rement les deux c t s de l vacuation sup rieure et les accrocher derri re les supports 7 3 et 7 2 1 en s assurant qu ils sont tous...

Page 22: ...he et l arr t le moteur aspiration vitesse minimale pour un rechange d air permantent particuli rement silencieux en cas de faibles va peurs de cuisson V2 Vitesse Vitesse moyenne pour la plupart des c...

Page 23: ...is avec la hotte Il ne sont pas lava bles ni r g n rables il faut les remplacer au moins tous les 4 mois d emploi ou plus fr quemment en cas d emploi particuli rement intense REMPLACEMENT FILTRE AU CH...

Page 24: ...436003931_01 070711...

Reviews: