Franke FDF 12174 Instructions For Use And Installation Download Page 8

 

 

 

 

 

EN 

8

 

USE

 

A

B

C

D

E

F

G

H

Control board 

Key Function 

Display 

Switches the extractor motor on and off at the 
latest  selected speed  

Indicates the selected speed. 

Decreases the suction speed. 

 

Increases the suction speed. 

 

By pressing this key it is possible to activate  
the intensive speed from any previously se-
lected speed. The intensive speed can be acti-
vated even when the motor is OFF. This speed 
has been timed at 10 minutes. After that time 
the system activates automatically the latest 
selected speed. This function is suitable for  
cooking conditions when vapours and smells 
are of the utmost emission.  

HI  

appears. The spot down on the right side 

flashes once a second. 

By pressing this key it is possible to set up the 
motor to a suction speed at 100 m

3

/h lasting 10 

minutes every hour. After this the motor 
switches off automatically. 
When the filter saturation is going on it is pos-
sible to  reset the alarm by pressing this key for 
about 3 seconds. The indication is visible only 
when the motor is off. 

 

Indicates the  

24-function. 

The spot down on 

the right side flashes and the motor is on. 

Once the process is finished  the previous indi-
cation disappears: 

FF

  Indicates that the metal grease filters 

saturation alarm has been triggered, and 
the filters need to be washed. The alarm 
is triggered after 100 working hours.  

EF

  Indicates that the charcoal filter satura-

tion alarm has been triggered, and the fil-
ter has to be replaced; the metal grease 
filters must also be washed. The charcoal 
filter is triggered after 200 working hours.  

By pressing this key it is possible to set the 
delayed shutdown of the appliance to 30 min-
utes. This function is suitable for a complete 
elimination of the residual smells. It can be 
activated at any position, and it is deactivated 
by pressing the key again or by switching off 
the motor. 

Indicates alternately the selected speed of the 
hood and the time left before the hood shut-
down. The spot down on the right side flashes. 

Turns the light on and off . 

 

Turns the light on and off at reduced intensity. 

 

 

Summary of Contents for FDF 12174

Page 1: ...truzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullanım ve montaj talimatları Davlumbaz Uživatelská Pøíruèka Odsavač par FDF 9174 FDF 12174 GB IT FR DE TR CZ ...

Page 2: ...E 17 SOMMAIRE CONSEILS ET SUGGESTIONS 19 CARACTERISTIQUES 20 INSTALLATION 21 UTILISATION 24 ENTRETIEN 25 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 27 CHARAKTERISTIKEN 28 MONTAGE 29 BEDIENUNG 32 WARTUNG 33 IÇERIKLER TAVSIYELER VE ÖNERILER 35 ÖZELLIKLER 36 MONTAJ 37 KULLANIM 40 BAKIM 41 OBSAH RADY A DOPORUČENÍ 43 HLAVNÍ PARAMETRY 44 INSTALACE 45 POUŽITÍ 48 ÚDRŽBA 49 EN IT FR DE TR CZ ...

Page 3: ...r than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance is not intended f...

Page 4: ...ic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 Air Outlet Connection Support 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 ...

Page 5: ...the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 305 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the w...

Page 6: ...tion insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 RECIRCULATION VERSION AIR OUTLET Insert the connection extension pieces laterally 14 1 in connec tion 15 Insert the Connector 15 into the Support bracket 7 3 and fix it with a screw Make sure that the outlet of the extension...

Page 7: ...n the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure ...

Page 8: ...y pressing this key for about 3 seconds The indication is visible only when the motor is off Indicates the 24 function The spot down on the right side flashes and the motor is on Once the process is finished the previous indi cation disappears FF Indicates that the metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working ho...

Page 9: ...t Switch off the hood and the lights If the 24h function has been activated this has to be deactivated Press the E key till the display is unlit Cleaning the filters Remove the filters one at a time holding them up with one hand and pulling the handle downwards with the other hand at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the f...

Page 10: ...1 flash with EF charcoal filter saturation alarm DEACTIVATED REPLACING THE CHARCOAL FILTER Reset of the alarm signal Switch off the hood and the lighting If the 24h function has been activated this has to be deactivated Press the E key until the display is unlit Replacing of the filter Remove the metal grease filters Remove the saturated charcoal filter by releasing the fixing hooks Fit the new fi...

Page 11: ...436003385_ver6 Franke S p a Via Pignolini 2 37019 Peschiera del Garda VR www franke it ...

Reviews: