![background image](http://html1.mh-extra.com/html/franke/fdb-9078-sil-k/fdb-9078-sil-k_instructions-for-use-and-installation_2327941007.webp)
EN
7
7
Hood body installation
• Before hooking the hood body it is necessary to tighten 2
Vr
screws
placed in the fixing points of the body.
• Hook the hood body on the
12a
screws.
• Tighten completely
12a
support screws.
• The correct hood body position can be levelled with
Vr
screws.
• Fix the hood definitively by tightening the
12a
security screws.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
9
ø 120
ø 150
AIR OUTLET - RECIRCULATION VERSION
• Connect the Flange ø150
10
to the bottom end of the Connec-
tor
15
• Join the Hood canopy outlet to the Flange on the bottom part of
the Connector, using a rigid or flexible pipe ø150 mm, selec-
tion of which is at the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has been
fitted.
ø 150
15
10