background image

2 | Instructions

Franke Kaffeemaschinen AG

8

User manual

2

INSTRUCTIONS

2.1

Installation

Installation may only be performed by an authorized Franke specialist.

Tasks

– Unpack the device
– Check that the required free space (50 mm) has been left behind the de-

vice

– Check the electrical power connection
– Connect connection lines and connection hoses
– Attach the device
– Connect the power supply
– Switch on the device
– Put the device into operation with the coffee machine

2.2

Function

The cooling unit has the following functions:

– Keeping the milk cool
– Displaying the milk temperature
– Preventing unauthorized access via a lockable door

2.3

Function of the FoamMaster

The FoamMaster has the additional following functions:

– Warming milk for the beverages
– Creating milk foam
– Automatic cleaning of the milk system
– Automatic monitoring of the fill levels

Summary of Contents for FCS4053

Page 1: ...Original operating instructions 20131925 02 11 21 2019 en USER MANUAL SU12 FCS4053 ...

Page 2: ...Read the user manual before working on the equipment Keep the manual with the equipment and pass the manual on to the next user if the equipment is sold or transferred to a third party ...

Page 3: ... 1 1 Intended use 4 1 2 Non authorized use 4 1 3 General safety concerns 5 2 Instructions 8 2 1 Installation 8 2 2 Function 8 2 3 Function of the FoamMaster 8 2 4 Operation and maintenance 9 2 5 Malfunctions 9 2 6 Transport storage decommissioning 9 2 7 Disposal 10 3 Technical data SU12 11 ...

Page 4: ...for operation indoors Please also observe the Declaration of Conformity delivered with the de vice Operate the cooling unit at ambient temperatures in the range of 16 43 C 1 2 Non authorized use Children under the age of 8 years are not permitted to use the device Children or persons who are challenged with respect to physical sensory or mental abilities must not use the device except under superv...

Page 5: ...ines or plug connections can lead to electrocution a Do not connect any damaged power cords lines or plug connections to the power supply b Replace damaged power cables lines or plug connections If the power cord is permanently attached contact the service techni cian If the power cord is not permanently attached order and use a new original power cord c Ensure that the machine and the power cord ...

Page 6: ...ay into drinks CAUTION Spoiled milk Spoiled milk could represent a health hazard a Use only fresh refrigerated milk b Observe the storage conditions for milk c Observe the shelf life of the milk used CAUTION Germs in unpasteurized milk Germs in unpasteurized milk could pose a health hazard a Do not use any unpasteurized milk b Only use pasteurized or long life milk Do you have any questions that a...

Page 7: ...of the milk container and the milk lid after sanitizing your hands or wear disposable gloves e Place the container lid with the suction hose on a clean surface only NOTICE Damage to the machine Connection lines could be damaged by tensile load Incoming moisture could cause damage An unsuitable location could lead to damage a Never pull on the connection lines b Lay the connection lines in such a w...

Page 8: ...es and connection hoses Attach the device Connect the power supply Switch on the device Put the device into operation with the coffee machine 2 2 Function The cooling unit has the following functions Keeping the milk cool Displaying the milk temperature Preventing unauthorized access via a lockable door 2 3 Function of the FoamMaster The FoamMaster has the additional following functions Warming mi...

Page 9: ...h warm water and a mild cleaner Use a dry cloth for drying or leave to air dry Do not use hot air Clean daily Interior chamber inner side of the door and lip seal Milk container Intake hose 2 5 Malfunctions Error messages will appear on the coffee machine s display in the case of malfunctions The error messages contain information regarding the cause and resolution of the malfunction 2 6 Transport...

Page 10: ...authorities for safe disposal of the refrigerant used The type plate contains information about the refrigerant The machine complies with European Directive 2012 19 EU regarding Waste Electrical and Electronic Equipment WEEE and must not be disposed of with household waste Dispose of electronic parts separately Dispose of plastic parts in accordance with their marking ...

Page 11: ... T 5 tropical climate suitable for operation at an ambient temperature 16 43 C Climate class N 4 temperate climate suitable for operation at an ambient temperature 16 32 C Noise emission 70 dB A Weight empty 25 7 kg Dimensions width height depth 340 mm 540 mm 475 mm Power cord 1800 mm Electrical connection data Type Country SU12 FCS4053 CH EU GB Voltage 220 240 V Frequency 50 60 Hz Power rating 17...

Page 12: ...ating 170 W Current consumption 0 8 A Fuse 10 A Connection 1L N PE Power cord 560 0005 151 SU12 FCS4053 JP Voltage 100 127 V Frequency 50 60 Hz Power rating 170 W Current consumption 1 33 1 7 A Fuse 10 A Connection 1L N PE Power cord 560 0004 859 SU12 FCS4053 USA CAN Voltage 100 127 V Frequency 60 Hz Power rating 170 195 W Current consumption 1 535 1 7 A Fuse 10 A Connection 1L N PE Power cord 560...