- 17 -
ZMI
_001_
2030
0203
57-A
Q
CT0064
_#SE
N
_#AQ
U
_#V
3.f
m
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!
Water flows conti-
nuously
– Solenoid valve cartridge faulty
➯
Replace it
– Flow rate regulator in shower head
blocked with scale
➯
Clean and
replace if
necessary
Water too hot
– Scald protection set incorrectly
➯
Set it
– Thermal element faulty
➯
Replace it
Water too cold
– Scald protection set incorrectly
➯
Set it
– Hot water flow blocked
➯
Open it
– Dirty filters/non-return valves
➯
Clean and
replace if
necessary
– Hot water supply pressure too low
➯
Check it
– Hot water temperature too low
➯
Increase it
– Thermal element faulty
➯
Replace it
Water volume too low
– Water volume regulator not fully open
➯
Open it
– Shower head blocked with scale
➯
Clean it
– Dirty filters/non-return valves
➯
Clean and
replace if
necessary
– Supply pressure too low
➯
Check it
Thermostat controls
unevenly
– Flow rate regulator in shower head
blocked with scale
➯
Clean and
replace if
necessary
– Thermal element dirty
➯
Clean it
Fault
Cause
Remedy
Summary of Contents for 2030020357
Page 85: ... 85 ZMI_001_2030020357 AQCT0064_ SNL_ AQU_ V3 fm Notes Notes Notas Annotazioni Notities ...
Page 86: ...ZMI_001_2030020357 AQCT0064_ SNL_ AQU_ V3 fm 86 Notes Notes Notas Annotazioni Notities ...
Page 87: ... 87 ZMI_001_2030020357 AQCT0064_ SNL_ AQU_ V3 fm Notes Notes Notas Annotazioni Notities ...