6
ZMI
_001_
2030
0085
26-A
Q
LT
0085
_#SE
N
_#AQ
U
_#V1
.f
m
10. Assembly Instructions
Warning!
Use the fitting only with non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
☞
Important!
When fitting the S-connectors, make sure that a distance of 150 mm is maintained
between the projecting S-connectors. Align the S-connections exactly horizontal.
The correct distances and the correct alignment of the S-connections must be made
at this point and must not be forced later on when installing the mixer unit.
10.1
Screw in and align the S-connections (a).
10.2
Install the screw-rosette (b).
Locking the spout
10.3
Slide the O-ring (c) over the fixation insert (d) of the spout.
10.4
Insert the long catch (e) into the mount (f).
10.5
Slide the spout (g) on to the the fixation insert (d).
☞
To be able to convert to a swivel spout later on, the short catch can be inserted into
the front groove of the mount, or it can be kept separately in a safe place.
10.6
Use to the screw (h) to fix the spout (g) in the catch (e).
10.7
Preparing a swivel spout
10.8
Slide the O-ring (c) over the fixation insert (d) of the spout.
10.9
Insert the short catch (j) into the mount (f).
10.10
Slide the spout (g) on to the the fixation insert (d).
☞
To be able to convert to a locked spout later on, keep the long catch in a safe place.
10.11
Use to the screw (h) to fix the spout (g) in the catch (j).
10.12
Insert the grit filters (k).
☞
Important!
Be careful to insert the grit filters the right way round.
10.13
Mount the fitting (m) with the union nuts (l).
10.14
Use a hollow hexagon wrench to open the water volume regulators (n).
o: Closed
p: Open
10.15