3.
fm
8. Dimensions
9. Assembly
Warning!
Protect the electrical connection with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
☞
Important!
The water connection must be off-centre and the cavity in the urinal must have a
minimum depth of 70 mm in the area around the water connection.
☞
If a faulty installation results in adjacent urinals interfering with each other, this can
be rectified by altering the sensitivity and by a selectable immunity mode
(see
9.1
Install the connection piece (a) leak-tight.
9.2
Install the solenoid valve (b).
9.3
Attach the hose (c).
9.4
Slide the urinal connector (d) onto the hose (c).
9.5
Check the function of the sensor (see
9.6
Secure the radar sensor (e) using the pre-installed hook strip on the siphon (f).
9.7
Connect the control unit (g) to the solenoid valve (h) and the radar sensor (e).
9.8
Connect the power pack (k) to the power supply (l, 230 V AC).
9.9
Install the urinal.
9.10
Install the siphon control unit.
9.11
Turn the water supply on.
9.12
Pour at least 2 l of water into the urinal.
• The first flush takes place after 10 seconds.
• The system is now operational.