3. Important notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided.
• Legal requirements and the technical connection regulations of the local water
supply companies must be complied with.
• Before assembling and installing the equipment, flush the supply pipes in accor-
dance with DIN 1988.
• Only use a 6 V lithium battery for the power supply.
• Forced flushing after 24 hours of non-use ensures the exchange of water in tap
lines and prevents the odour seal in the urinal drying out. This function can be
switched off with the optional remote activation unit. This function is switched on
at the factory.
• Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
• All rights reserved to make technical alterations.
4. Technical specifications
5. Scope of delivery
Nominal diameter:
DN 15
Flow pressure:
1.0 – 4.0 bar
Calculation flow rate:
0.30 l/s
Flushing flow:
0.30 - 0.70 l/s
Flush water volume:
2 – 4 l adjustable
Flush duration:
0.6 – 6.5 s (adjustable in 6 steps)
Operating voltage:
6 V lithium battery CR P2
Type of protection:
IP 65
Quantity
Description
1
Urinal flusher
incl. 6 V lithium battery and blockable flow
volume regulator
1
Flushing pipe
1
Urinal connector
1
Rosette
1
Installation and operating instructions