Contents 

 

 

 

 

 

 

 

 

Page 

 
 
 

1. 

Application 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. 

Technical data  

 

 

 

 

 

 

 

 

 

 

 

 

 

3. 

Description 

 

 

 

 

 

 

 

 

 

 

3.1 

Construction   

 

 

 

 

 

 

2-3 

 

3.2 

Function 

 

 

 

 

 

 

 

4-7 

 

 

 

4.  

Installation 

 

 

 

 

 

 

 

 

4.1 

Location 

 

 

 

 

 

 

 

 

4.2 

Assembly dimensions  

 

 

 

 

 

 

4.3 

Connecting the machine 

 

 

 

 

 

 
 

5. 

Operation 

 

 

 

 

 

 

 

10 

 

5.1 

Cleaning and preserving agent 

 

 

 

 

10 

 

5.2 

Nozzles and recoil forces 

 

 

 

 

 

10 

5.3 

Working pressures and spray flow rates 

 

 

 

11 

 

5.4 

Operating temperature 

 

 

 

 

 

11 

 

5.5 

Selection of the cleaning program 

 

 

 

 

11 

5.6 

Works setting   

 

 

 

 

 

 

12 

5.7. 

Commissioning 

 

 

 

 

 

 

12-14 

5.8. 

Taking the machine out of order 

 

 

 

 

14 

5.9 

Restarting of the machine 

 

 

 

 

 

15 

 
 

6. 

Maintenance   

 

 

 

 

 

 

15 

 

6.1 

High-pressure pump   

 

 

 

 

 

15 

 

6.2 

Water filter, cleaning agent filter 

 

 

 

 

15 

 
 

7. 

Troubles, causes and troubleshooting  

 

 

 

16-17 

 

8.  

Checking 

 

 

 

 

 

 

 

18 

 
 

9. 

Prevention of accidents 

 

 

 

 

 

18 

 

 
 

10. 

Safety instructions 

 

 

 

 

 

 

18 

 

 
 

Summary of Contents for FEM 718 MSE-Z

Page 1: ...cherheitshinweise lesen und beachten Read the instruction sheet and the safety instructions before putting into operation and observe them Avant mise en route de l appareil lire et respecter les instr...

Page 2: ...es and recoil forces 10 5 3 Working pressures and spray flow rates 11 5 4 Operating temperature 11 5 5 Selection of the cleaning program 11 5 6 Works setting 12 5 7 Commissioning 12 14 5 8 Taking the...

Page 3: ...capacity 18 kW 30 kW Water temperature after max 70 C heating period about 17 minutes 10 minutes Constant temperature 40 C 55 C Supply voltage 400 V 3N AC 50 Hz 230 V 3 AC 50 Hz Rated load at a heat...

Page 4: ...er tank made of stainless steel with electrical gilled pipes high pressure pump with electric motor cold water tank and a separate master control cabinet On the pressure side the machine is equipped w...

Page 5: ...4 3 2 Function 3 2 1 Functional diagram...

Page 6: ...er has been activated The spray gun is opened by activating the lever When the lever is released the gun is closed preventing any further release of fluid from the spray lance When the gun is closed d...

Page 7: ...switches off the machine in the event of the spray gun being closed The second pressure switch starts the machine when the spray gun has been opened after the pressure has fallen to approx 20 bar The...

Page 8: ...ain the time sequence starts from zero After the time to be set on a time relay has gone by the operating condition is deleted For restarting the machine the start button on the control box at the was...

Page 9: ...8 4 2 Assembly dimensions...

Page 10: ...maximum volume flow of the corresponding machine type 4 3 3 Long distance piping The long distance piping is to be carried out by a skilled fitter for oil and water systems Only components of the FRA...

Page 11: ...ump pressure and to the direct connection of a high pressure hose pipe DN 8 x 10 m The appropriate nozzle size is to be taken from the table below For long distance pipings and or longer hose pipes la...

Page 12: ...e set to maximum 70 C 5 5 Selection of the cleaning program to be done on the control box of the washing bay Start button programe COLD Button for programe HOT A Button for cleaning agent A or B for p...

Page 13: ...ipe and set main and emergency switch to 1 Operate and deaerate the machine with cold water without the adding of cleaning agents for about 1 minute at zero pressure For this purpose set turning butto...

Page 14: ...below the cleaning agent level in the tank The desired cleaning agent A or B can be selected on the button of the control box at the washing site A T T E N T I O N When the cleaning agent tank is emp...

Page 15: ...nning for at least 1 minute with cold water but without the addition of cleaning agents to flush out all chemical residues Release safety lever of the spray gun close spray gun The machine is switched...

Page 16: ...s but at the latest after 3 months of operation For lubrication use branded oils of SAE 90 quality only When changing the oil remove the draining screw drain the oil and dispose it properly Then put t...

Page 17: ...w or excessive voltage Provide required voltage overcurrent release switches off Excessive pump pressure See under Trouble Excessive overcurrent release switches off pump pressure Threephase current m...

Page 18: ...blocked Remove and clean nozzle flush spray lance without nozzle Wrong spray nozzle Mount correct nozzle No flow of cleansing Cleansing agent filter Fill up cleansing agent or agents on suction hose...

Page 19: ...rrying parts or to the machine Do not operate the machine with defective high pressure hose or defective electrical wires The machine must not be operated by children or untrained persons 10 Safety in...

Page 20: ...min approx Constant temperature 35 C approx Mains supply 400 V 3N AC 50Hz 230 V 3 AC 50 Hz Nominal consumption 23 kW 35 A 23 kW 61 A Noise emissions 80 dB A measured outside at a distance of 1 m from...

Page 21: ...ating period 8 min approx Constant temperature 48 C approx Mains supply 400 V 3N AC 50Hz Nominal consumption 35 kW 53 A Noise emissions 80 dB A measured outside at a distance of 1 m from the machine s...