![Franconia FC 02 User Manual Download Page 11](http://html1.mh-extra.com/html/franconia/fc-02/fc-02_user-manual_2326741011.webp)
Only when the init is made, all the commands will be available.The menu bar contains the main
commands. The following table explains each menu item on the menu bar in order from left to right:
Menu
Item
Shortcut
Function
Turntable
Limits
Enter limits of movement of the turntable in degrees
Offset
Enter offset of movement of the turntable in degrees
Start init
Start an initialisation run of the turntable
Antenna
Limits
Enter limits of movement of antenna mast in m
Offset
Enter offset of movement of antenna mast in m
Start init
Start an initialisation run of the antenna mast
Program
Load settings
Strg+L
Load settings
Save settings
Strg+S
Save current settings
Info
Show program version
Quit
Strg+Q
Exit the application software
Turntable controls
The software limits of the turntable can be lowered if needed. As a factory setting theses values are set to
max. –200° and + 200°. We have defined this value in order to avoid any problems with the cables of the
equipment under test if the turntable makes a complete tour on itself.
MA_FC02_(Rev2_1) - 9/06 / Version 1 / Rev:2.1
11 / 24