If the safety thermostat trips on 

  Switch  off  the  power,  turn  off  the  gas  and  wait  for  the 

appliance to cool down completely.  

  Find  and  remove  the  cause  of  overheating.  If  necessary, 

contact qualified personnel. 

  Open the inspection door and use a screwdriver to press the 

reset  button  on  the  safety  thermostat  inside  the  connector 
until you hear a "click" (see Fig. 3.3.1). If the appliance does 
not restart, or the safety thermostat continues to trip, switch it 
off and contact technical service.     

Fig. 3.4.1 

                                                                                                                                                         

ATTENTION!

 

The unit delivers a high temperature air flow. Do not place any flammable objects 
or materials within 2 m of the air outlet.  During normal operation, and for some 
time  after  shutdown,  some  parts  of  the  machine  can  reach  very  high 
temperatures! Always use suitable personal protective equipment. 

 

Stop 

 

Operation  with  a  thermostat:  the  heater  stops  automatically  when  the  desired 

temperature is reached. Manual operation: cut off the power to the heater  by turning 
the switch, if fitted in the system, to the OFF position.   

 

Seasonal use 

 

G Max 

heaters are mainly intended for seasonal use. At the end of the winter season, or in general if 

the appliance is not used for long periods:  
   

Disconnect the appliance from mains and close the gas supply valve. 

Thoroughly  clean  both the  external surfaces  and  the  internal  parts (fan,  burner,  etc.  see  also 
Par. 4.1 and 4.2). 

Close the air inlet and outlet vents with the sliding panels provided with the unit. 

If necessary, cover the heater with a protective sheet to protect it from the weather. 

At the beginning of the next winter season, before using the appliance again: remove the cover, 
the closing panels, restore the electrical and gas connections and carry out a complete functional 
check of the machine.    

 
 

3.4 How to use the thermostat socket  

 

The G Max heater is equipped with a socket located on the side of the electrical 
box  for  connecting  an  external  switching  device  (room  thermostat,  timer, 
control unit, etc.).  
For the remote control of burner ignition and shutdown, connect the device to 
terminals 1 and 2 of the thermostat plug, supplied. 
For manual operation, connect an On/Off switch to the power supply line of the 
appliance and insert the cap with internal jumper between terminals 1 and 2, 
supplied with the unit, into the thermostat socket. 

 

 
 
 
 
 
 
 
 
 

CLICK! 

Fig. 5.4.1  

 

Summary of Contents for G Max

Page 1: ...HEATER T R A N S L AT I O N O F O R I G I N A L I N S T R U C T I O N S E N G L I S H C O U N T R Y O F D E S T I N AT I O N Read this manual carefully before installing and operating the unit Rev 00...

Page 2: ...1 12 Warranty 9 1 13 Manufacturer s identification data 9 1 14 Declarations 9 1 15 Declaration of conformity 10 2 INSTALLATION 11 2 1 Preliminary operations 11 2 2 Positioning 11 2 3 Fire prevention...

Page 3: ...the device with wet or damp hands Do not pull the power cords or expose them to a risk of shearing Do not leave the device directly exposed to the weather rain sun etc In case of failure or malfunctio...

Page 4: ...ontact the manufacturer support francosrl com for support 1 5 Target readers This manual is intended for the installer the operator and qualified personnel authorised to service the machine OPERATOR m...

Page 5: ...ompliance with the laws in force in the Country of destination of the machine Mechanical maintenance technician qualified technician able to operate the machine under normal conditions to make it work...

Page 6: ...circle impose a PROHIBITION OBBLIGATION Pictogram Description Dangerous electrical voltage General hazard Hot surfaces danger Do not remove safety guards and devices Do not clean oil grease repair or...

Page 7: ...ignition sequence checks the presence of flame during operation and locks the machine out in case of anomalies Safety thermostat with manual reset protects the appliance from overheating by switching...

Page 8: ...trical panel Fig 1 3 Fan Safety thermostat Sensing ignition electrodes Nozzle Handling brackets Burner reset button Room thermostat socket Pipe connection power supply gas M Schuko plug CEE 7 4 Thermo...

Page 9: ...lls and positioning the lifting belts correctly 1 12 Warranty This product is guaranteed for 12 months from the date of manufacture for all faults attributable to a proven manufacturing or material de...

Page 10: ...following European Directives 2006 42 EC Machinery Directive EU 2016 426 Gas Appliances Regulation Cert n CE51CS4822 issued by IMQ 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibi...

Page 11: ...a distance from the wall on a suitable support structure The guidelines provided are purely indicative the optimal position of the air heater in relation to the room to be heated must be chosen by the...

Page 12: ...g inlet and outlet ducts Fig 2 2 2 Wall installation with air recirculation or external suction n 20 self tapping screws hexagonal head flanged 4 2x13 Bracket Washer Grower Washer Screw M8 Bracket Fla...

Page 13: ...sent The following table shows the theoretical values of the fresh air flow rate to be introduced into the environment according to the installed thermal power in order to maintain a CO2 concentration...

Page 14: ...if necessary a pressure regulator parts not supplied Only use an approved flexible hose with a maximum length of 2 m for the connection and make sure it is free of restrictions Do not use metal tubin...

Page 15: ...in the technical data tables for the type of gas used Start the heater by setting the room thermostat to the desired temperature or in the case of manual operation by powering up the appliance via an...

Page 16: ...To start the heater set the room thermostat to the desired temperature or with manual operation power up the appliance by turning the switch provided in the electrical system to ON During operation In...

Page 17: ...nal use G Max heaters are mainly intended for seasonal use At the end of the winter season or in general if the appliance is not used for long periods Disconnect the appliance from mains and close the...

Page 18: ...iodically check the tightness of screws and bolts especially in the presence of unusual noises and vibrations 4 2 Cleaning and replacing the nozzle Open the inspection door unscrew the nozzle from the...

Page 19: ...h 3000 Gas consumption 1013mbar 15 C G20 methane G30 G31 propane butane m3 h kg h 6 67 5 07 Gas pressure G20 methane G30 G31 propane butane mbar mbar 20 28 30 37 Nozzle diameter G20 methane G30 G31 p...

Page 20: ...d Maintenance Manual 20 5 2 Spare parts list Use only original spare parts Orders should be placed specifying at least the following Appliance model Mfg year Spare part number Quantity Shipping addres...

Page 21: ...IT W FIXING SCREWS 8 4202050 1 COMPLETE BURNER 8a 4202062 1 BURNER FIXING KIT 9 7302003 1 IGNITION SENSING ELECTRODES 9a 1257500 1 FIXING KIT FOR IGNITION SENSING ELECTRODES 10 8102000 1 GAS PIPE 11 4...

Page 22: ...HER 4 4202055 1 COMPLETE GAS VALVE 5 7302100 1 FLAME CONTROL BOARD 6 1454215 1 RELAY 7 7301100 1 FUSE HOLDER 8 7304002 1 FUSE 5X20 STD 6 3A 9 4202056 1 TERMINAL BOARD 9a 4205000 1 WIRING KIT 10 700400...

Page 23: ...5 1 Technical data Make sure that all electrical connections on the terminal block and on the components are firmly secured that the box cover is well closed and that the closing screws are tightened...

Page 24: ...or and fan can rotate freely Check voltage at motor terminals Replace if necessary Previous trip of an external thermal motor protector if applicable Check that the motor rotates freely inspect the ai...

Page 25: ...d outlet Insufficient or excessive installed heating power for the room to be heated Review plant dimensioning The heater locks out or stops during operation Power failure Check the electrical system...

Page 26: ...ion and Maintenance Manual 26 Faulty flame control device safety thermostat or flow switch tripping even if there is no problem Check operation of components clean contacts check connections replace i...

Page 27: ...G Max Operation and Maintenance Manual 27...

Page 28: ...al 28 FRANCO s r l headquarters and factory Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 Fax 39 0171 612337 www francosrl com info francosrl com For any question you are welcome to...