INSTRUCTION MANUAL FOR 
USE AND MAINTENANCE 

 

 
 

UCP Fly  

HUMIDIFIER/COOLER 

 

 

 

T R A N S L A T I O N   O F   O R I G I N A L   I N S T R U C T I O N S  

E N G L I S H

 

 

Read this manual carefully before  

installing and operating the machine 

 

Rev. 00/2022 Franco s. r. l.                                                                                         Via Nazionale, 80 - 12010 Cervasca (CN) 

Summary of Contents for 3108000

Page 1: ...CE UCP Fly HUMIDIFIER COOLER T R A N S L A T I O N O F O R I G I N A L I N S T R U C T I O N S E N G L I S H Read this manual carefully before installing and operating the machine Rev 00 2022 Franco s...

Page 2: ...fication data 9 1 14 Declarations 9 1 15 EC Declaration of Conformity 10 2 INSTALLATION 11 2 1 Preliminary operations 11 2 2 Positioning 11 2 3 Electrical connections 12 2 4 Hydraulic connections 13 3...

Page 3: ...nce Do not use accessories spare parts or components not intended for or supplied by the manufacturer Avoid touching the device with wet or damp hand Do not pull on power cables or expose them to risk...

Page 4: ...ones in all copies owned The Manufacturer is responsible for the original version in Italian in the event of any doubts regarding the translated versions please refer to the Italian language and conta...

Page 5: ...ifting and handling equipment and machines strictly following the manufacturer s instructions in accordance with the laws in force in the Country of destination Mechanical maintenance technician quali...

Page 6: ...circle impose a PROHIBITION OBBLIGATION Pictogram Description Dangerous electrical voltage General danger Do not remove safety devices It is forbidden to clean oil grease repair or adjust moving part...

Page 7: ...ds on many variables such as temperature ambient humidity and air distribution The water pressure required is that of the water mains 2 4 atm 0 2 0 4 MPa This machine must only be used for the purpose...

Page 8: ...centrifugal humidifier Fig 1 10 2 Fig 1 10 2 Rotary disc Disc cap Tank cover Rear cover Float valve Pump Nozzle Motor Water connection Regulating valve Drain hole with connection quick and cap Fixed...

Page 9: ...f manufacture for all faults attributable to a proven manufacturing or material defect The warranty does not cover all parts damaged by transport bad or incorrect maintenance neglect inability to use...

Page 10: ...with the following European Directives 2006 42 EC Machinery Directive 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibility Directive Harmonised standards and reference specificati...

Page 11: ...n must comply with the applicable European national and local standards in force In particular follow the requirements of standard UNI 8884 Characteristics and treatment of water in cooling and humidi...

Page 12: ...erations requiring the removal of protections must be carried out exclusively by qualified personnel after having stopped the machine and disconnected the power supply 2 3 Electrical connections Elect...

Page 13: ...a hose barb Fig 2 4 1 To arrange for periodic draining of water from the tank bleed off a remove the drain plug by pushing up the stop ring This operation can be facilitated by using a 10 mm hexagona...

Page 14: ...used must not exceed 35 C 3 3 Start up As soon as the machine is powered up the motor fan and pump start up The pump circulates the water to the rotating disc which nebulises it and the fan generates...

Page 15: ...er can cause the growth of harmful bacteria and microorganisms It is therefore necessary to prevent stagnation As well as for safety reasons regular water renewal is also necessary to keep the applian...

Page 16: ...s case Disconnect the pump as described above Turn the swivel ring to the unlock position and remove it Remove the rotor and impeller and clean them with lukewarm water and a brush Any limescale depos...

Page 17: ...ic ring nut and remove the float body Position the new float and adjust it so that the water level inside the tank completely covers the pump Reassemble the assembly repeating the sequence in reverse...

Page 18: ...IP56 IP56 IP56 Weight kg 10 10 10 Air flow rate m h 750 1100 1800 Power W 320 340 380 Voltage V Hz 230 50 230 50 230 50 Current A 1 8 1 9 2 0 60Hz Versions H15 H20 H25 Atomisation capacity l h up to...

Page 19: ...characteristics Insert a thermomagnetic differential circuit breaker on the power line upstream of the equipment Also ensure that all electrical connections have been made in accordance with the inst...

Page 20: ...d maintenance manual UCP Fly 20 6 SPARE PARTS LIST Use only original spare parts When ordering spare parts always specify Machine model Year of construction No of series Part number Quantity Shipping...

Page 21: ...CP FLY H25 41a 6003007 WASHER DIN 125 A 4 3 1 41b 6003007 WASHER DIN 125 A 4 3 4 42 3101020 PROTECTION GRID 1 43 1800008 PUMP SPACER 1 Pos Code Description Qty 1 6002004 SCREW 4 2x9 5 DIN 7981 3 2 180...

Page 22: ...for the motor to cool down and restart the appliance The rotating disc and the fan turn but the water is not sprayed Pump power failure Check the pump supply line Water supply circuit is disconnected...

Page 23: ...User and maintenance manual UCP Fly 23...

Page 24: ...anual UCP Fly 24 FRANCO s r l Headquarters and factory Via Nazionale 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 www francosrl com info francosrl com For reports or requests please contact us at...