regulator filter opening in order to collect the oil
contained in the regulator,
- remove the filter cover plate located under the
regulator (# 4 of fig. 8) with a screwdriver,
- remove the tubular filter from the regulator. Clean, if ne
it with oil using a soft brush, never a wire-brush,
- replace the filter in the regulator, install the cover plate
and secure with the screw.
• Clean all the enamelled panels of the stove with a dry
or slighly damp soft cloth.
• Use a soft clean cloth to wipe the front glass when the
unit is running at a low burning rate. When the main
door is opened for cleaning, the flame will be disturb,
and turn to a yellow flame. Clean quickly, but gently.
Close the door, the flame will return to a normal burning
position.
N.B. :The appearance of cracks when burning the
enamelled units is quite usual and tends to disappear
when the appliance is cooling down. It should not be
considered as a defect but rather as a patina of the
enamel which does not affect its quality nor its service
ability.
3.7. Trouble shooting
SYMPTOM
PROBLEM
−
TEST SOLUTION
Flames extinguish during
lighting.
¤ Ve r y co ld chim ney. No draft
established.
−
- Leave door ajar until fire has caught.
- Check air supply in the room.
Fire extinguishes once
firestarter has burnt off.
¤ Fuel tank is empty.
−
- Fill tank.
¤ Fuel valve is closed.
−
- Open valve.
¤ Main regulator float not engaging.
−
- De-press the safety lever.
¤ Control knob is set on “0"
−
- Adjust control knob to ”1".
Fire extinguishes during use.
¤ Fuel tank is empty.
−
- Fill tank.
¤ Insufficiant draft.
þ
−
- Call your installer.
Flame is excessely large,
smokey and sooty.
¤ Fuel adjustment made too quickly.
−
- Return control knob to “1"; wait for normal combustion.
(catalyser should glow red) Wait 5 to 15 minutes between
each adjustment.
Stove burns noisily,
extinguishes and relights itself.
¤ Burner contains excess fuel.
−
- Adjust to lower setting. If problem persists call your
installer.
¤ Insufficient fuel.
−
- Check that the de-scaler, the regulator filter and burner
pot are cleaned.
Fire smokes.Soot build up
noticed. Flame imbalance
¤ Insufficient air supply.
−
- Increase fresh air supply (open door, window; add make
up air supply).
¤ Downdraft or blockage in chimney.
þ
−
- Check Chimney for Soot build up. clean if necessary.
- Ensure chimney height is sufficient and cap is not
affected by any nearby obstructions.
- Room is in negative pressure. Increase fresh air supply.
Check draft with draft meter and adjust if not to
requirements. See page 4.
¤ Oil flow is too low on 1 setting.
þ
−
- Adjust low flow rate while control is set on “1", call your
installer.
¤ S t ov e i s n o t l eve l. Fla me
imbalance.
−
- Check level. Adjust if necessary.
¤ Catalyser not centered. Uneven
f u e l d i s t r i bu t i o n r es u l t i n g in
secondary air shortage.
−
- Center catalyser assembly
¤ Insufficient fuel.
−
- Check that the de-scaler, the regulator filter and burner
pot are cleaned.
¤ The draft regulator is blocked in
open position
þ
−
- Unlock the draft regulator.
- Check the regulator adjustment (p. 6) and refit, if
necessary.
Coke build up noticed.
¤ Excessive air supply.
−
- Adjust draft.
þ
: This sign means that you should
asked for a qualified engineer to do the
work.