3.2 Lighting

Figure

 7

-

Slide the air control (# B and C).

-

Open the front door and lay firelighters or rolled up
newspapers on the grate with a reasonable quantity, if
necessary, of dry kindling wood. Place 2 or 3 small
logs on top.

-

Light the newspaper or firelighters using a long taper
and close the front door.

-

When the fire is burning fiercely, add further logs of a
diameter up to 10 cm.

-

When the stove body is very hot, close the lower air
control (# C).

-

The burning rate can now be adjusted by moving the
top air control to the left (# B).

Experience will show you which settings are best for
your situation.

3.3 Operating procedure

The appliance must function with the door properly
closed

, the burning rate being controlled in using the

secondary air regulation flap (rep. B).
Experience will show you which settings are best for
your situation.
The airwash system works with the top airslide. When
the top airslide is full open the system works at its
strongest efficiency.
The more closed down the airslide is, the less effective
the airwash will be (when shut down completely, the
airwash system can not function).

Loading the fuel

-

The door should be opened slowly, avoiding a sudden
rush of intake air, so that smoke does not escape into
the room.

-

The logs must be placed on the glowing embers.

-

For a briskly burning fire, there should always be at
least two logs in the fire. The fire will burn better if
there are several logs.

-

For a slower burning fire (for example, at night), select
larger logs.

-

After loading the firebox, close the main door (rep. A,
figure

 7

, page 7).

3.4 De-ashing

-

Ashes must be removed regularly.

-

Ashes must never be allowed to pile up to the grate.
The grate would not be cool down and could rapidly be
damaged.

-

Empty the ashes when the appliance is cold.

-

Remove the ash drawer using the tool provided.

-

Empty the ashes carefully with regard to the live
embers.

3.5 Maintenance of the Chimney

Very important !

In order to avoid any incident

(chimney fire, etc...), maintenance tasks must be
carried out regularly.

If the appliance is regularly used, the chimney
should be swept several times per year, together
with the stovepipe connection section.
If the chimney catches fire, you must cut off the flue
draught, close the doors and windows, hatches and
keys and call the Fire Brigade without delay.

DO NOT OPEN THE DOOR OF THE APPLIANCE

(OR AIR INLET) UNDER ANY CIRCUMSTANCES.

The chimney must be serviced and cleaned by a
specialist.

3.6 Maintenance of the stove

The appliance must be cleaned regularly, together with
the connecting pipe and the flue pipe.

Open the door and remove all deposits in the firebox
and clean the removable fire grate.

Cleaning of the glass door can be done with a soft cloth
dampened with water and vinegar or potassium ; this
must be done when the appliance is cold ; then rinse
with clear water.

Do not use abrasive cleaners

.

The “vitroceramic” glass will resists to temperatures of
up to 750 C. Should the glass break due to misuse, it
must be replaced by the manufacturer own product.

All the casing parts can be cleaned using a soft cloth
either dry, or slightly damp. In case of condensation or
water splashes clean the parts before they dry out.

Check that there are no obstructions before relighting
after a long period of disuse.

The appliance must not be used with a flue serving
several appliances.

Keep the grates ventilation free of any obstruction.

The baffle plates should be removed regularly and any
ash or deposits cleaned away.

Ashes must not be allowed to build up.

The door rope seals should be checked annually and
replaced when required.

3.7 Safety advice

This appliance produces heat and may cause severe
burns if touched.
The stove may still be

HOT

even when the fire has burnt

out.

KEEP CHILDREN AWAY.

A FIRE GUARD IS ADVISABLE TO PROTECT

CHILDREN THE ELDERLY AND INFIRM.

8

Technical manual “1274”

“SAVOY MK2” - model : 134 08 09

Instructions for user

Summary of Contents for SAVOY MK2 ELEGANCE 134 08 09

Page 1: ...rtificate Document n 1274 8 20 09 2011 Multifuel stove Norm DIN EN 13240 2005 10 Model 134 08 09 Output 8 kW Technical manual to be saved by the user for future reference FR EN NL IT SAVOY MK2 ELEGANC...

Page 2: ...ant to burn wood or solid fuel safely WARNING Incorrectly installed this appliance can be dangerous and possibly cause serious accidents We recommend that you engage the services of a professional eng...

Page 3: ...mity with DIN EN 13240 2005 10 Intermittent burning heating appliance Detachable flue spigot for rear or top chimney connection Front loading door fitted with large refractory glass panel Adjustable p...

Page 4: ...te this load Make sure they are not combustible or covered with combustible material as per the Building regulations There must be a clearance of at least 150 mm at each side of the appliance and at t...

Page 5: ...combustible material walls cross members It must permit an easy sweeping 2 4 Mounting the flue collar The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer...

Page 6: ...e utilisation check Check that the seals of the smoke line are in good condition Check that the door closes correctly Check that the glass is not damaged Check that the smoke passages are not obstruct...

Page 7: ...or infirm people 3 1 Fuel This appliance is not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calor...

Page 8: ...ard to the live embers 3 5 Maintenance of the Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used...

Page 9: ...mall wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Ro...

Page 10: ...10 Technical manual 1274 SAVOY MK2 model 134 08 09 Note Note...

Page 11: ...38 Reducing plate A B C D 01 23 237406 Reducing plate A B C D 01 24 237427 Reducing plate A B C D 01 25 259015 Fixing plate A B C D 04 26 262607 Heat shield A B C D 01 27 270402 Air control flap A B C...

Page 12: ...Technical manual 1274 SAVOY MK2 model 134 08 09 Spare parts Figure 8 Spare parts view 20 50 21 7 51 51 6 0 52...

Page 13: ...42 327910 MK Tray D 01 43 331132 EF Main door A 01 43 331132 RH Main door B 01 43 331132 RP Main door C 01 43 331132 MK Main door D 01 44 332004 Air duct A B C D 01 45 352176 EF Top plate A 01 45 352...

Page 14: ...e exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or...

Reviews: