Monte Carlo - réf. 134 12 07
6
Technical manual "1291"
stovepipe, and the flue, must be leak tight.
- For the premises equipped with a mechanical
controlled ventilation, the airtightness has to prevent
the exhauster drawing out the smokes from the
exhaust gas pipe.
- The connection pipe and any draught stabiliser
must have access for cleaning.
2.6. Pre-utilisation check
Check the condition of the filler seals, that the door
closes correctly , that the window is not damaged, that
the smoke passages are not obstructed by pieces of
packaging or removable parts.
Make sure that all removable parts are correctly
installed.
Note :
all gaskets ceramic ropes, seals, are consumable
parts and must be changed on a regular basis by the
user.
2.7. Maintenance of the Chimney
Very important
: To avoid accidents (chimney fire,
etc.), regular maintenance should be carried out.
If the stove is regularly used, the chimney should
be swept several times per year, together with the
stovepipe connection section.
If the chimney catches fire, you must cut off
the flue draught, close the doors and windows,
hatches and keys and call the Fire Brigade
without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE
(OR AIR INLET) UNDER ANY CIRCUMSTANCES.
Chimney condition
should be checked at least
once per year by a professional engineer.
2.8. Removing and replacing the flue
baffle
(figure 5 et 6)
- Open the front door
- Remove the fuel retainer
- Remove the 2 screws (#1)
- Remove the 2 screws (#2)
- Remove the flue baffle (#3)
Removing and replacing the flue baffle, if needed, if
must be necessary, replace 2 gasket (see p. 12 n°15)
and replace the flue baffle in the reverse order.
Figure 5 - Removing the flue baffle
Figure 6 - Replacing the parts
3
2
1
3
2
1