![FRANCO BELGE Hekla 634 10 44 Technical Manual Download Page 9](http://html1.mh-extra.com/html/franco-belge/hekla-634-10-44/hekla-634-10-44_technical-manual_2326689009.webp)
2.8. Flue baffle mounting
Install flue baffle (attached on hearth grate before
leaving the plant) inside combustion chamber (fig.13).
-
First slide section
A
over front dampers then lay
section
B
on hearth decoration plate.
-
The pins
4
have to be located behind the brackets.
2.9. Access to the fans
(Ref.634 10 44)
•
Figure 14
:
Open the main door (
1
) and to withdraw the ashtray (
2
),
to
remove the 4 screws (
3
) and to deposit the grids
right-hand side and left (
4
).
To go up them, proceed in the opposite order.
2.10. Maintenance of the chimney
Very important :
In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly.If the appliance is used frequetly,
the chimney and the lower part of the hob where the flue
pipe is connected must be swept several times a year.
The chimney must be checked out at least twice a year.
Technical manual “1204”
9
“Hekla” - ref. 634 10 44/634 10 45
Installation instructions
A
B
A
B
2
1
3
4
4
4
1
Figure 13 - Flue baffle
4
3
4
1
2
3
Figure 14 - Access to the fans
1
- Flue baffle
2
- Hearth decoration
plate
3
- Wedge
4
- Pins
1
- Door.
2
- Ash-pan
3
- 4 screws.
4
- Grate.