background image

1. Description of the unit

1.1. Package

- 1 package : Stove complete

- 1 package : Ground vat and mirrors

1.2. Specifications

Nominal Heat Output (NF D 35-385)

. . . . . . . . . . . . . . . . . . . . . . . . kW   10
. . . . . . . . . . . . . . . . . . . . . . Btu/hr   34,130

Oil consumption at : . . . . . . . . . . . . . . .
- maximum speed . . . . . . . . . . . . . litre/h 1,25

. . . . . . . . . . . . . . . . . . . . Imp gal/hr   0.275
. . . . . . . . . . . . . . . . . . . . US gal/hr   0.33

- minimum speed . . . . . . . . . . . . . litre/h 0,25

. . . . . . . . . . . . . . . . . . . . Imp gal/hr   0.055
. . . . . . . . . . . . . . . . . . . . US gal/hr   0.066

Chimney draft required at : . . . . . . . . . . .
- maximum speed . . . . . . . . . . . . . . Pa 20

. . . . . . . . . . . . . . . . . . . . . . in.w.g.   0.0802

- minimum speed . . . . . . . . . . . . . . Pa 6

. . . . . . . . . . . . . . . . . . . . . . in.w.g.   0.024

Weight . . . . . . . . . . . . . . . . . . . . kg   118

. . . . . . . . . . . . . . . . . . . . . . . . lbs   260

Flue outlet diameter (O/D) . . . . . . . . . mm 120/125

. . . . . . . . . . . . . . . . . . . . . . . . . in   5

1.3. Description

Flued oil stove with vaporizing burner (Norm EN1)

Ø 120/125 mm

(5")

620 mm (24 1/2")

402 mm (16")

544 mm (21 1/2")

505 mm

(20")

678 mm

(27")

383 mm(15")

Ill. 1 - Dimensions in mm

SAFETY NOTICE

: Read carefully all instructions

before starting the installation. If the stove is not
properly installed, a house fire may result. For your
safety, follow the installation directions. Contact local
building or fire officials about restrictions and
installation inspection in your area.

Document n° 809-5EN ~ 15/04/1999

Oil burning stove Burgundy

Technical manual 15

Summary of Contents for Burgundy 174 10 25

Page 1: ...MERVILLE Phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications Burgundy Oil burning stove 174 10 25 174 10 31 EN1 NF D 35 385 Fran ais p 1 12 English p 13 24 Descr...

Page 2: ...f the handle 16 Fitting the visioflamme 16 External tank 17 Oil flow adjustment 17 Chimney draught 18 Maintenance of the Chimney 18 Operating instructions 19 Fuel 19 Lighting procedure 19 Operating pr...

Page 3: ...ight kg 118 lbs 260 Flue outlet diameter O D mm 120 125 in 5 1 3 Description Flued oil stove with vaporizing burner Norm EN1 120 125 mm 5 620 mm 24 1 2 402 mm 16 544 mm 21 1 2 505 mm 20 678 mm 27 383...

Page 4: ...ainted or blued steel pipe of not less than 30 gage 304 grade stainless steel of not less than 30 gage or 1 mm viterous enamelled steel with a maximum diameter of 5 inch O D 127 mm It is the installer...

Page 5: ...regulating knob on 1 and let the burner run for a few minutes The flame must completely cover the bot tom of the burner and the catalyser body must be glowing red hot If the flame is too small the sto...

Page 6: ...ic damper located at the back of the stove 1 ill 8 The reading of the draught must be done once the unit is hot minimum 30 minutes of use Refer to the specifications page 15 for minimum draught requir...

Page 7: ...til the burner is completely cool before repeating the lighting procedure 3 4 Shutting down Set dial to the 0 position 1 ill 9 Raise the safety lever of the regulator Allow the flame to burn out compl...

Page 8: ...valve is closed Open valve Main regulator float not engaging De press the safety lever Control knob is set on 0 Adjust control knob to 1 Fire extinguishes during use Fuel tank is empty Fill tank Insu...

Page 9: ...Oil tight nut A B C D 02 16 165124 Float regulator A 01 16 165139 Float regulator B C D 01 17 179605 Regulator shaft A B C D 01 18 181604 Ceramic rope 10x4 A B C D 1 m 19 181615 Ceramic rope 12 A B C...

Page 10: ...3 26 29 30 39 45 12 31 5 8 9 19 5 36 42 43 50 2 6 10 22 35 40 44 48 71 46 52 51 50 53 54 28 57 55 56 58 59 57 60 61 68 63 64 65 66 67 66 65 64 63 62 62 20 70 69 47 Ill 10 Stove exploded view Document...

Page 11: ...y C 01 53 202801 Support B C D 01 54 445902 Fixing plate B C D 01 55 303301 Bearing A B C D 01 56 909401 Sliding door A B C D 01 57 325304 Reducing plate A B C D 02 58 327801 Clamp A B C D 01 59 72561...

Page 12: ...recommen ded in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic anomalies explosions etc Electric...

Reviews: