This appliance is meant to burn wood or coal safely
Warning
An incorrectly installed wood stove can cause serious accidents.
We recommend that you engage the services of a professional engineer for its installation
and the regular maintenance requirements
1. Product information
1.1. Package
•
1 package : Stove complete.
1.2. Optional equipment
•
Set of 4 long legs.
1.3. General characteristics
FUEL : WOOD
Chimney draught required . . . . . . Pa
12
Heated volume . . . . . . . . . . . . m
3
130
Grate dimensions :
- width . . . . . . . . . . . . . . . . mm
270
- depth . . . . . . . . . . . . . . . . mm
200
- usable height . . . . . . . . . . . . mm
240
Max. log size
- Length maxi . . . . . . . . . . . . . cm
25
Ash pan capacity . . . . . . . . . . litres
3
Net weight . . . . . . . . . . . . . . kg
77
Flue gas temperature . . . . . . . . . °C
290
- Nominal output . . . . . . . . . . . kW
4,5
- Efficiency . . . . . . . . . . . . . . . %
74,3
- Co (13% O2) . . . . . . . . . . . . . %
0,36
- Flue gas mass flow . . . . . . . . . g/s
5
- Fuel rate . . . . . . . . . . . . . . kg/h
1,5
FUEL : ANTHRACITE (SMOKELESS-FUEL)
Tested with fuel brand name “phurnacite” entering in
catégory A, table B2 from the standard EN 13240
- Nominal Heat Output . . . . . . . . kW
5,6
- Chimney draught required . . . . . Pa
12
- Flue gas temperature . . . . . . . . °C
339
- Flue gas mass flow . . . . . . . . . g/s
5,4
- Efficiency . . . . . . . . . . . . . . . %
73,6
- Co (13% O2) . . . . . . . . . . . . . %
0,14
- Fuel rate . . . . . . . . . . . . . . kg/h
0,9
1.4. Description
Multifuel stove.
In conformity with DIN EN 13240 : 2005-10
.
•
Intermittent-burning heating appliance.
•
Wood burnt on grate.
•
Wood and anthracite burning stove.
•
Close cast iron firebox.
•
Removable appliance, to be installed near a wall.
•
Detachable flue spigot for rear or top chimney
connection.
•
Detachable top for easy handling and cleaning (rear
smoke exit only).
•
Adjustable air controls for controlling the burning rate.
•
Spin wheel for lighting.
•
Large ash-pan.
•
Grate shaker control.
1.5. Principle of operation
T h e
“
B e l f o r t
”
i s
designed for operation
with the door closed.
Heat is mainly diffused
by radiation, through the
window and body of the
appliance.
Combustion occurs on
the grate, with draught
entry through the top of
t h e
c o m b u s t i o n
chamber when using
wood and under the
g r a t e
w h e n
u s i n g
smokeless fuels.
Technical manual “1174”
3
“BELFORT” - ref. 134 04 11
Product information
420
550
409
Ø 125
131
340
Ø 139