2.5. Pressure testing
The gas pressure to the stove must be measured at the
burner test nipple.
For Natural gas this is 18.5 mbar measured with the
appliance in the full rate position.
2.6. Coals layout
Only the ceramic coals supplied with this appliance are
to be used. The coals should only be laid as shown on
this p age. Rep lace ment coals and ceramic are
available from your dealer, but should be installed by a
competent person (e.g. Corgi registered).
Please ensure that when fitting the matrix and coals,
that you DO NOT OBSTRUCT THE PILOT
FRANCO BELGE accept no responsibility for any injury
sustained whilst handling hot ceramics.
Instructions for the layout of the prefixed ceramic
matrix and loose coals for Belfort fitted with gas
burner unit.
Parts : 1 Ceramic mat, 9 Ceramic coals.
Figure 5
-
Place the ceramic matrix (rep. 3) above the ceramic
mat, on the supports, onto the top of the burner body.
Figure 6
-
Place 4 coals on top of the matrix (A) as shown in (B).
-
Place the remaining 5 coals as shown in (C).
1
2
3
5
4
3
3
A
B
C
Installation instructions
Figure 5 - Fitting the ceramic matrix
1 - Back wall of the combustion chamber
2 - Burner
3 - Matrix
4 - Burner holes
5 - Pilot
Figure 6
Fitting the medium ceramic coals and the upper ones
Belfort
Model 154 05 08
6
Technical manual