background image

2

Technical manual “1187”

Belfort Flueless GN - ref. 154 03 05

FRANCO BELGE congratulates you on your choice.

FRANCO BELGE, which has been granted the ISO 9001 certification, guarantees the quality of its

appliances and is committed to meet its customers’ needs.

FRANCO BELGE, which can boast a 75-year experience in the industry of heating devices, uses

state-of-the-art technologies

to design and manufacture its whole range of products.

This document contains instructions on how to install your appliance and make full use of its

functions, both for your comfort and safety.

CONTENTS

Description of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 3

Package . . . . . . . . . . . . . . . . . . p. 3
Specifications . . . . . . . . . . . . . . . p. 3
Dimensions . . . . . . . . . . . . . . . . p. 3

Operating principle . . . . . . . . . . . . p. 3
Safety advice . . . . . . . . . . . . . . . p. 4
Principle of Operation . . . . . . . . . . p. 4

Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 5

Check the stove . . . . . . . . . . . . . p. 5
General Fitting Notes. . . . . . . . . . . p. 5
Ventilation. . . . . . . . . . . . . . . . . p. 5
Clearance requirements . . . . . . . . . p. 5
Connecting the gas supply. . . . . . . . p. 6

Pressure Testing . . . . . . . . . . . . . p. 6
Door Lock . . . . . . . . . . . . . . . . . p. 7
Ceramic Fuelbed Layouts . . . . . . . . p. 7
Commissining the Stove . . . . . . . . . p. 7

Instructions for user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 9

Manual Tap . . . . . . . . . . . . . . . . p. 9
Remote Control (Simple version) . . . . p. 9
Recommandations . . . . . . . . . . . p. 10
Safety devices. . . . . . . . . . . . . . p. 10

Maintenance . . . . . . . . . . . . . . . p. 10
Servicing Instructions . . . . . . . . . . p. 10
Trouble shooting . . . . . . . . . . . . p. 10

Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 12

Summary of Contents for 154 03 05 Belfort Flueless GN

Page 1: ...0 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM RCS Colmar SIREN 444 881 953 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 00 Fax 00 333 28 43...

Page 2: ...all your appliance and make full use of its functions both for your comfort and safety CONTENTS Description of the unit p 3 Package p 3 Specifications p 3 Dimensions p 3 Operating principle p 3 Safety...

Page 3: ...gory G20 I2H Heat Input gross kW 3 5 Heat Input net kW 3 1 Supply Pressure mbar 20 Burner Pressure mbar 18 Gate Rate max m3 hr 0 330 Gate Rate min m3 hr 0 180 Injector 220 Weight kg 55 1 3 Dimensions...

Page 4: ...full protection for young children or the infirm extra protection should be considered for these conditions conforming to BS 6539 or BS 6778 Bearing in mind that the heat given off by this appliance...

Page 5: ...inadvertent covering by a rug or carpet This may be achieved by either the hearth being 50 mm above the level of the floor or a fender or kerb around the hearth to a height of 50 mm The appliance must...

Page 6: ...connections to the appliance until all supply pipes have been purged to expel any dust or debris View on under side of stove to show final connection of 8 mm pipe to stove Although a gas soundness te...

Page 7: ...ort Flueless Stove Coal Layout Parts 1 Ceramic mat 12 Ceramic coals Place the ceramic matrix on top of the ceramic mat on the top of the burner body Place 4 coals on top of the matrix as shown in A Pl...

Page 8: ...8 Technical manual 1187 Belfort Flueless GN ref 154 03 05 Notes Notes...

Page 9: ...to the highest setting large flame The appliance is now burning at its highest operating output Running the appliance at low setting Ignite permanent pilot and run appliance at High setting for a min...

Page 10: ...on the appliance must only be done by a C O R G I registered engineer a Open the door b Remove all matrices from top of burner c Remove mat from top of burner and discard d Remove any debris from the...

Page 11: ...ecessary The thermocouple When the unit is started up the pilot light flame goes out when the handle is turned from the ignite position to the pilot light position The thermocouple is not at a high en...

Page 12: ...panel 01 11 310737 EF R side panel 01 12 359818 EF Front plate 01 13 110404 Hinge pin 6X30 02 14 189713 Screw M8X30 01 15 134258 Bushing 01 16 300118 EF Leg 04 17 300480 Base 01 18 124412 Strut M8X45...

Page 13: ...t Flueless GN r f 154 03 05 Spare parts 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 4 3 3 3 5 3 6 3 7 4 1 4 0 3 9 3 8 4 2 4 3 4 3 4...

Page 14: ...eption of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in co...