The join between the connection pipe and the
stovepipe, and the flue, must be leak tight.
-
For the premises equipped with a mechanical
controlled ventilation, the airtightness has to prevent
the exhauster drawing out the smokes from the
exhaust gas pipe.
-
The connection pipe and any draught stabiliser must
have access for cleaning.
2.6 Mounting the tray
Figure 4
To avoid damage during transport, the tray has been
stored behind the main door.
Centre the tray on tab “
A
” and lower into place.
2.7 Pre-utilisation check
-
Check that the seals of the smoke-line are in good
condition. Check that the door closes correctly. Check
that the glass is not damaged. Check that the smoke
passages are not obstructed by packaging or
removable parts. Check that all removable parts are
correctly installed.
Note :
if it acts of a ceramics braid, it is consumable and
thus brought to be changed by the user.
2.8 Maintenance of the Chimney
Very important !
In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly.
If the appliance is regularly used,
the chimney should
be swept several times per year, together with the
stovepipe connection section.
Chimney condition should be checked at least once
per year by a professional engineer.
6
Technical manual “1219”
“ARDENNES” - model 134 15 01
Installation instructions
A
Figure 4 - Mounting the tray