8 - Maintenance and Servicing
To prolong the service life and performance of your searchlight, the following maintenance
guidelines are recommended:
◼
Maintenance checks should be conducted before every voyage or at least every three
months.
◼
Before checking, disconnect the equipment from the supply.
◼
Visually inspect the condition of the equipment.
◼
Any major or minor structural damage should be rectified immediately to reduce
sympathetic wear.
◼
After inspection it may be necessary to clean the inside of the searchlight. The following
procedure should be adhered to:
◼
Remove the front bezel.
◼
Clean the front glass inside and out using a proprietary glass cleaner.
◼
Clean the reflector if required.
◼
Ensure that the lampholder is free from corrosion or other damage.
◼
It is advisable to check all seals and gaskets for signs of degradation. Renew if necessary.
◼
The searchlight is fitted with a breather unit. This ensures a steady airflow to prevent any
vacuum forming within the barrel.
◼
Upon completing all maintenance requirements, the searchlight should be tested for full
working order (approximately 20 minutes).
If in any doubt as to the correct servicing procedures to adopt, please contact your
distributor/agent or the manufacturer who will be able to advise the best course of
action for your product.
Notes for Lamp Fitting/Removal for LX300RC 150w Xenon
To fit lamp:
◼
Remove lamp from packaging.
◼
Remove front bezel from searchlight by unfastening the latches.
◼
Pass the Negative end of the lamp through the ring terminal attached to the black cable
and screw into the lamp holder.
◼
Place the front lead ring terminal (red cable) over the front of the lamp (positive) and
secure in position using the lamp heatsink.
◼
Now screw the PTFE insulator into the lamp heatsink and ensure that the lead is tightly
secured to prevent any arcing.
◼
Place the PTFE bush over the insulator and fix mechanism in position by pushing the
retaining clip through the insulator.
◼
Replace front bezel and fasten down clips securely.
Reverse this procedure for lamp removal.
.