P5G-2UE
Normal Power Factor
P5G-2UE Series
Model - 9030
When will a Secondary-Circuit
Ground Fault Protection P5G-2UE
Series Transformer NOT trip:
u
Ground faults on the primary
(line) side of the transformer.
Secondary-Circuit Ground-
Fault Protected
Transformers will NOT
provide protection against
electrical shock.
u
Series arcs in the sign system
(arcs associated with
defective tubing
interconnections or between
sign tubing sections).
u
Breaks in the sign tubing,
degassed tubing, or opens in
the high voltage connections
without a corresponding short
or arc to ground.
u
Shorts to an ungrounded metal
part within or near a sign.
NEON TRANSFORMER WITH
UL2161 COMPLIANT SERVICE
SWITCH
A push button style service switch
is located on the end of the case
opposite the primary bushing. To
activate service mode: while the
transformer is on, depress and hold
the switch for 1 second and
release. The tubing will flash on 3
times to indicate the transformer
is in service mode (SCGFP circuit
is disabled). The tubing should then
remain on. The tube may not light
if the tube is broken or shorted.
The LED will constantly flash while
unit is in service mode. The unit
remains in service mode for 29
minutes. After 29 minutes, the unit
will return to normal mode. To
escape service mode before the
29 minutes has elapsed, depress
the service switch and hold for 1
second and release, or turn power
off, wait 3 seconds, then turn power
on. The unit will restart in normal
mode.
P5G-2UE UNITS CAN BE FLASHED AND DIMMED.
P.O. Box 300
2268 Fairview Blvd.
Fairview, TN 37062
Email: [email protected]
Voice: 800-753-2753
Fax: 615-799-3199
WT/62196
06/13/06
SECONDARY
TERMINAL
HOT LINE
(BLACK OR RED)
GTO IN
CONDUIT
NEON TUBING
SERVICE
SWITCH
SECONDARY
TERMINAL
SERVICE
GROUND
(GREEN)
NEUTRAL
(WHITE)
GTO IN
CONDUIT
LED
GTO IN
CONDUIT
SERVICE
SWITCH
SECONDARY
TERMINAL
NEON TUBING
GTO IN
CONDUIT
SERVICE
GROUND
(GREEN)
NEUTRAL
(WHITE)
HOT LINE
(BLACK OR RED)
LED
SERVICE
SWITCH
GTO IN
CONDUIT
NEON TUBING
GTO IN
CONDUIT
GTO IN
CONDUIT
HOT LINE
(BLACK OR RED)
SERVICE
GROUND
(GREEN)
NEUTRAL
(WHITE)
LED
P5G-2UE Series
Models -
15030, 15060, 9060
SECONDARY
TERMINAL
HOT LINE
(BLACK OR RED)
NEUTRAL
(WHITE)
GTO IN
CONDUIT
SERVICE
SWITCH
SERVICE
GROUND
(GREEN)
GTO IN
CONDUIT
LED
NEON
TUBING
The P5G-2UE is a universal
transformer: 15kV and 9kV
units can be used in place
of 30mA or 60mA
transformer with the
following voltage ratings:
15030: 10000 - 15000 volts
15060: 10000 - 15000 volts
9030: 2000 - 9000 volts
9060: 3000 - 9000 volts
9 mm
Ne
18 - 32
1 - 18
@ 15 mm pressure
22 - 39
1 - 22
10 mm
Ne
21 - 36
1 - 21
@ 13 mm pressure
25 - 44
1 - 25
11 mm
Ne
24 - 40
1 - 24
@ 12 mm pressure
28 - 48
1 - 28
12 mm
Ne
26 - 45
1 - 26
@ 11 mm pressure
31 - 54
1 - 31
13 mm
Ne
29 - 50
1 - 29
@ 10 mm pressure
33 - 60
1 - 33
14 mm
Ne
30 - 54
1 - 30
@ 10 mm pressure
36 - 64
1 - 36
15 mm
Ne
33 - 60
1 - 33
@ 9 mm pressure
40 - 72
1 - 40
18 mm
Ne
40 - 72
1 - 40
@ 8 mm pressure
45 - 80
1 - 45
TUBING
DIAMETER
TYPE
TUBING
Luminous Tube Footage Chart
1
Based on average grade.
2
All enclosed applications. Exposed and extremely cold
climates may require footage be reduced by 10-20%.
NOTE 1: Deduct approximately 1 foot from above figures for each pair of electrodes.
NOTE 2: Recommended gas pressure for 10-ft plus lengths. Increase 10% for tube
lengths under 10 ft.
Hg
2
Hg
2
Hg
2
Hg
2
Hg
2
Hg
2
Hg
2
Hg
2
TUBING LENGTH RANGE (feet)
1
5 - 18
6 - 22
6 - 21
7 - 25
7 - 24
8 - 28
8 - 26
9 - 31
9 - 29
10 - 33
9 - 30
10 - 33
12 - 40
11 - 40
14 - 45
11 - 36
9030 P5G-2UE
9060 P5G-2UE
15030 P5G-2UE
15060 P5G-2UE
Standard Series Wiring Method
Virtually-Grounded Series Wiring Method
Virtually-Grounded Series Wiring Method
Standard Series Wiring Method