10
rubber hose holder using first a 3-4 mm dia. drill and then an 8 mm dia. drill. For the connection, it should
possibly be used a silicon pipe having 14 mm internal diameter. On the bottom of the machine, just facing
the rubber hose holder there is a hole for the passage of the drain pipe
5. PERIODICAL MAINTENANCE
FILTER CLEANING
The only required periodical maintenance is the cleaning of the filter once every month, or more often
(even every two weeks) if the room is very dusty or the dehumidifier is working for many hours every day.
The cleaning must be done by placing the fitter under a water jet with the drilled panel facing the floor
so that the water jet may push the filter towards the drilled panel.
Note: You can require spare fitters from your dealer's service.
HUMIDITY CONDENSED IN 24 HOURS IN DIFFERENT CONDITIONS
model
FLIPPERDRY 300
5 lit.
7 lit.
7 lit.
10,5 lit.
10 lit.
15 lit.
19 lit.
20°C,60%R.H. 20°C,80%R.H. 25°C,60%R.H. 25°C,80%R.H. 27°C,65%R.H. 30°C,80%R.H. 32°C,90%R.H.
in relation to the room temperature and r. humidity
model
FLIPPERDRY 300
230/1/50
250
6-35 35-100
300
5,5
300
R134a
22
35x32x70
Power
supply
V/n/Hz
power
con-
sumption
W (*)
functioning
temperature
range °C
functioning
relative
humidity
range.%
air
volume
mc/h
Tank
capacity
litri
room
volume
(indic.) mc
ecological
refrigerant
Weight
Kg
size
LxPxH
cm
6. TECHNICAL DATA
note: The average power consumption has benn calculated in 20°C - 60% R.H.. room
Summary of Contents for FLIPPERDRY 300
Page 1: ...FLIPPERDRY 300 ...
Page 2: ...2 ...
Page 19: ...19 7 FLIPPERDRY 300 ...
Page 20: ...20 ...