background image

 

 

 

 

 
 

 

FDNF62 DEHUMIDIFIER 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

USER AND MAINTENANCE MANUAL 

 

 
 
 

FRAL AUSTRALASIA 

PO Box 5071 

Port Macquarie   New South Wales    2444 

Australia 

 
 

Summary of Contents for FDNF62

Page 1: ...FDNF62 DEHUMIDIFIER USER AND MAINTENANCE MANUAL FRAL AUSTRALASIA PO Box 5071 Port Macquarie New South Wales 2444 Australia ...

Page 2: ...on and moving should be avoided Moving whilst connected to power could cause water to come into contact with electrical parts It is therefore recommended to remove the plug from the socket before moving the dehumidifier Correct Distance this dehumidifier draws in the air from the back and lets out through the front side grill therefore the back panel which supports the air filter must be kept at a...

Page 3: ...uted by according to safety and electro magnetic compatibility to European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006 95 CE 12 12 2006 ELECTROMAGNETIC COMPATIBILITY EMC 2004 108 CE 15 12 2004 It is hereby certified that this Dehumidifier conforms to the IEC Regulations CEI EN 60335 2 40 CEI EN 55014 1 55014 2 The machine is built...

Page 4: ... Current at 35 C 95 rh standard ver 4 4 A Locked Rotor Current LRA 20 Air Flow 650 cm h Noise level at 3 meters 51 dB Refrigerant R134a Standard Defrosting Control System Electronic Hot Gas Defrosting Control System optional Electronic thermostat Water Tank Capacity 12 kg Continuous Drainage Pipe Connection 25mm Temperature Range standard version 7 35 C Temperature Range hot gas defrost system 1 3...

Page 5: ...RELAY 2 F1 3 ACL 5 LE2 6 LE1 4 LE3 1 ACN M1 ev M2 fan LEGEND 1 COMPRESSOR 2 FAN MOTOR 3 ELECTRONIC CARD 4 HUMIDISTAT ELECTRONIC 5 MICRO SWITCH 6 ELECTRO VALVE 7 THERMOSTAT 8 HOUR COUNTER ...

Page 6: ...tor 2 again through the heat exchanger or condenser 3 Finally the fan motor 4 expels the air back into the room through the front grill panel The condensed water is collected in the tank 5 A micro switch 6 stops the machine when the water in the tank reaches the correct level by raising the water float lever The humidistat 7 starts the functioning of the dehumidifier when the humidity is higher th...

Page 7: ...POWER will switch on confirming correct supply of power to the machine If the light WORKING is still off turn knob on the control panel clockwise until the light WORKING is ON The light DEFROST PAUSE will also switch on and after about 5 minutes the dehumidifier will start dehumidifying When the red light is ON ALARM the machine will not start one must check that the water tank is empty and that i...

Page 8: ...fting pump This allows condensed water to be drained into a floor waste or similar The pump will work automatically controlled by a ball cock placed inside the pump Before moving the machine remember to purge water from water tank If the pump cannot work correctly the compressor stops and the green light turns on In this case check the pipe situation Maximum head working pressure of the pump is ab...

Reviews: