Connect the BUS RS-485 of the ca mera to the back panel of the DVR.
Press “MENU”, than “SETUP” and “ RS-232/422/485
Setup” on the DVR for enter to the BUS configuration
and enter the same Protocol (Model) and Baud Rate of
the PTZ ca mera .
RS-232/ 422 /485 Setup
COM Port
RS-232
RS-422/485
De vice Type
PTZ
Model
Pelco (D-Type )
Baud Rate
4800
Data Bit
8
Stop Bit
1
Parity
None
DVR/Camer a ID
0
Press “MENU” , than “SETUP” and “Pre-Ca mera
Setup” on the DVR and enter the ID Address of the
single PTZ ca me ra.
ATTENTION: Ple ase be sure that all c amer as have
di fferent ID Address.
Pre-Camera Setup
REC Resoluti on
720x288
Water mark
√
Gr oup
Camer a
Installe d
PTZ ID
1 2 3 4 5 6 7 8
1
√
N/A
2
√
1
…
…
…
Now the ca mera it is correctly connected to the DVR and is possible to manage it using the remote controller, mouse or the
PC software.