background image

3DG-2S2-2T

Operating instructions

Summary of Contents for 3DG-2S2-2T

Page 1: ...3DG 2S2 2T Operating instructions...

Page 2: ...or close to sources of heat in dusty atmospheres or when it could be exposed to corrosive substances High temperatures or overheating could compromise the product functions and life Handle with care K...

Page 3: ...odule can be housed in the 3DGFlex unit and enables creating 2 channels in DVB T or DVB C standard beginning from the stream of 1 2 or 3 satellite transponders QPSK DVB S2 In fact 2 DVB T or DVB C mux...

Page 4: ...button 3 PRODUCT INSTALLATION 3 1 PACKAGING CONTENTS All interno dell imballo sono contenuti i seguenti materiali modulo 3DG avvertenze per la sicurezza e l installazione del prodotto 3 2 MODULE ASSE...

Page 5: ...use a PC to program the module by web interface The module can be reset to default parameters see the control unit s instructions ATTEN TION the default language is English After resetting you can se...

Page 6: ...ser code default is 1234 To change the 3DG 2S2 2T language enter the main menu in the control unit LANGUAGE and select the required language pressing For all the programming activities and to understa...

Page 7: ...7 English Operating instructions...

Page 8: ...8 English Key Only for module configuration in DVB T Only for module configuration in DVB C...

Page 9: ...9 English Operating instructions Key Only for module configuration in DVB T Only for module configuration in DVB C...

Page 10: ...to check whether the receiver has locked the signal or not Network name reading only to check the transponder name BER to view the BER quality of the input signal SNR to view the signal interference...

Page 11: ...s set on OFF the output signal is deactivated Spectrum to regulate the spectrum as NORMAL or INVERTED according to the reception instrument that could only function with one of the two modes Normally...

Page 12: ...he order criteria for the program lists INPUT ordered by classification to the input number SAT1 SAT2 BP LCN ordered by LCN i e according to the number associated to the program no matter what input i...

Page 13: ...ice ID to view the program service ID Advanced configurations Select country to select the installation country TSID to view and change the ID associated to the transport stream by the broadcaster The...

Page 14: ...ontinue to function is the last one that was opened IMPORTANT to access programming from the web interface the control unit must be outside the main menu logo 3DGflex Fracarro shown on the display NOT...

Page 15: ...s The 3DG 2S2 2T module specifically shows the symbol V if the enabled inputs have a signal and the receiver has locked it the symbol The 3DG 2S2 2T module specifically shows the symbol V if the enabl...

Page 16: ...sponder is locked and finally the name of the locked multiplexer For the output indications are given about the use of the available band for each mux In detail bitrate used and available in numeric f...

Page 17: ...xtended frequency or in 1IF of the transponder to be received According to the selected frequency for the setting the corresponding polarity can be selected The last item is used to set the symbol rat...

Page 18: ...n this case we can have the program decrypted by the CAM by flagging the box There are keys below the program table to reset the CAM access the common interface menu display the CAM messages and set t...

Page 19: ...Sending enable changing the CAM decrypt management by choosing from the methods in the dropdown menu if the third option CAPMT Resize is enabled by flagging the box the CAM is set for decrypting only...

Page 20: ...le in the previous position The right hand section also displays certain information about the input signal including if it is locked or not the network name network ID original network ID and the tra...

Page 21: ...the Overflow Alarm With the single tone function active channel input has no effect Standard DVB C For this standard the parameters we have to set vary considerably with respect to the previous one N...

Page 22: ...bles regarding the list of input programs the MUX 1 output and the MUX 2 output The lines in the first input program table on the left show all the programs coming from the various inputs INPUT 1 INPU...

Page 23: ...he previous item and enables setting the LCN value for televisions with mpeg4 tuner which means they are able to tune in the high definition channel in the standard position With a tangible example we...

Page 24: ...set the program so that it is declared as Free to air or encrypted by the decoder Always automatic the program is automatically declared free to air if it is decrypted by the cam Always yes the progr...

Page 25: ...X PID configuration beneath each mux output table the following screen opens The 2 tables enable adding or removing the PID to and from the output mux In the first Added PID list we can write the PID...

Page 26: ...grams according to the LCN or LCN HD parameters Auto SID Remapping if enabled this innovative function allows automatically resetting a new progressive SID for the programs therefore enabling to chang...

Page 27: ...ing decrypted by the CAM because certain set top boxes may be unable to identify that the contents are effectively decrypted and therefore they could not be viewed In this case it is advisable to use...

Page 28: ...ing screen opens First of all in the Monitoring settings section enable the required function The other parameters are then set in the other sections in particular those regarding the SMTP server the...

Page 29: ...he modules and in the green option bar at the top select Configuration Monitoring Status the following screen opens In this screen the time interval and number of attempts can be set for monitoring th...

Page 30: ...meter the monitoring can be enabled the alarm message text can be personalized that will be sent and for certain parameters the function range i e the minimum and maximum tolerated values can be set I...

Page 31: ...selected where the configuration is copied from and the module where it should be copied to In the green option bar at the top select operations save configuration on file on USB drive to open the fol...

Page 32: ...ion The USB drive where the configuration has been saved or loaded must be in the control unit USB port and not in the card port In the green option bar at the top select operations factory default or...

Page 33: ...rate exceeds the maximum limit the module generates a bitrate overflow with the risk that the selected programs are not distributed correctly To know the maximum available bitrate refer to the followi...

Page 34: ...be made when setting the muxes to ensure they do not overlap each other The module must be programmed so that it is an insensitive as possible to an increase in bitrate of one or more programs include...

Page 35: ...k in this case the available peak bitrate will be zero This reset can also be done on the control unit after entering the module menu go to Output select the mux in question the Bitrate submenu and th...

Page 36: ...distributed 5 4 FIRMWARE UPGRADE The 3DG 2S2 2T module can be upgraded directly and remotely via the web The direct upgrade procedure involves loading the firmware previously saved on a USB drive dire...

Page 37: ...37 English Operating instructions The following screen opens Select the correct firmware file and wait for it to load after which the modules can be selected that need upgrading...

Page 38: ...ted in the following screen If a general upgrade is required this operation is not required just press on Upgrade modules in the previous screen When the upgrade has been launched the following screen...

Page 39: ...ions Firmware Upgrade and Upgrade Results as shown in the following screen When the module is turned on for the first time check the software release is the most recent one available in the fracarro c...

Page 40: ...quency steps 250kHz Output frequency accuracy 30kHz Output level from 3DG BOX 100dB V Output level regulation 0 to 15dB Channel flatness 1 5dB Spurious level 40dBc adjacent channels 50dBc non adjacent...

Page 41: ...llowing harmonized standards including all applicable modifications 2004 108 EC Electromagnetic Compatibility Directive EMC 2006 95 EC Low Voltage Directive LVD Information given in this manual is pre...

Page 42: ...42...

Page 43: ...43 Note...

Page 44: ...Fax 33 1 47283421 Fracarro UK Ltd Unit A Ibex House Keller Close Kiln Farm Milton Keynes MK11 3LL UK Tel 44 0 1908 571571 Fax 44 0 1908 571570 Garantito da Guaranteed by Garanti par Garantizado por Ga...

Reviews: