in case of suction in the place or on the system, protect the intake pipe using a suitable
filter
with maximum filtration of 25µm.
For the use of filters with filtration different from 25µm, ask FPZ. Check compliance with the maximum pressure / vacuum data
giv
en in the SPECIFICATIONS (max ∆p).
•
for use as a
blower
deduct the pressure loss (P
a
) from the
maximum compression indicated (max ∆P ), i.e. P
working
≈ max ∆P -
P
a
(for T
ambient
=20°C and P
ambient
=1013 mbar)
•
for use as an
exhauster
make sure the maximum vacuum at the inlet port is not exceeded.
SPECIAL VERSIONS
3.2
FPZ side channel blowers/exhausters can be manufactured in special or custom versions; the instructions given in this manual still
apply to some of them.
The special versions manufactured, and for which that given above applies, are:
•
BPA version
Machines built to work in harsh environments and/or for conveying aggressive fluids, where aggressive means the presence
of elements that can affect standard machine operation, such as humidity; as specified in point 2, conveying flammable,
explosive or toxic gases, or installation in potentially explosive places, is not permitted.
•
TMS version
Machines that ensure mechanical seal between the parts that convey air or fluids, minimising leakage.
•
Special electric motors
On request, blowers/exhausters can be manufactured with motors having one or more of the following characteristics:
-
Special voltages
-
Higher levels of protection against solid bodies and/or liquids (standard IP55)
-
Higher insulation classes (standard Class F)
-
Protection devices such as thermal switches, heaters, PTC, PT100
•
Energy Efficient motors
The side channel blowers/exhausters can be manufactured using high efficiency, premium efficiency.
Further customisation must be requested and agreed when ordering, subject to a feasibility appraisal by the Technical Department.
PROHIBITIONS
3.3
THE FOLLOWING IS STRICTLY PROHIBITED:
-
Using the unit in installations for unforeseen use.
-
The suction and conveying of aggressive, corrosive and/or harmful fluids.
-
Using the unit in conditions different from the values given in the "SPECIFICATIONS" and RATING DATA.
-
Using the unit without having installed the suction filter.
-
Operation with inlet and/or outlet port closed.
-
Making conversions or changes to the unit, maintenance or repair work on own initiative or not envisaged in the manual.
Maintenance work can be carried out only in compliance with that described in this user manual, exclusively by qualified personnel.
IT IS COMPULSORY TO:
- Check and comply with the intended use of the machine.
- Check and comply with the conditions of use specified in this manual.
- Comply with the installation conditions specified in this manual.
- Carry out the preliminary checks as specified in the section "STARTUP".
- Carry out maintenance as specified in section 7.
REASONABLY FORESEEABLE IMPROPER USE
3.4
•
Listed below are some examples of improper use identified by risk analysis and practical experience, according to the conditions
they can create.
ATTENTION!
For maintenance of special version machines, contact FPZ.
Non-compliance with the unit’s intended use can cause serious accidents.
Failure to comply with the prohibitions/obligations can result in technical faults, damage to the system or accidents.
Danger of serious injury!
IMPROPER USE
CONSEQUENCES
RISKS
IMPROPER USE LINKED TO NORMAL OPERATION
Failure to comply with the distance for the
motor air intake
Motor overheating and possible damage to
the blower
RISK FOR THE MACHINE
Presence of operators and possible contact
Operator coming into contact with hot parts
RISK FOR THE OPERATOR