![FPG visair Product Manual Download Page 16](http://html1.mh-extra.com/html/fpg/visair/visair_product-manual_2325934016.webp)
Part No. 30911 Rev. A September 2020
- 16 -
Visair Refrigerated Cabinets
Interior
cont.
VISAIR CABINETS - CLEANING
Cleaning the
Base Cavity
With the base tray pulled out, sweep out, or
use a vacuum cleaner, to remove any debris
from the base cavity.
A Wet-and-Dry vacuum cleaner should be
used, since there is likely to be some water
in the bottom.
Fan Deck and
Drain Hole
After removing the fixing screws, the fan
deck can be lifted and unplugged from the
cabinet for thorough cleaning.
Be careful not to trap the cables when it is
replaced.
Check the drain hole is clear of debris.
Condensate
Capacity
Warning
When cleaning, DO NOT fill the well with liquid or attempt to hose it out, as the
condensate tray will overflow and leak onto the floor.
Cooling Coil
and Probes
With the back plates removed, the cooling coil is
exposed. No cleaning is normally required, but if there
is any debris visible, carefully remove it with a vacuum
cleaner.
Be very careful not to bend or distort the fins of the
cooling coil, as this would reduce the airflow.
Also be careful not to move or disturb the location of the
two temperature probes. One is in free air, and the
other is inserted between the fins of the coil.
Continued on next page