User manual

version 1.0

SERInet

                

converter RS485 / Ethernet

power supply passive PoE or 9-32V

communication indication on the serial
line

galvanic separation RS485 / ETH

installation on the DIN rail (2 modules)

Terminals RJ15 for RS485

1

www.

foxtron

.eu

Summary of Contents for SERInet

Page 1: ...0 SERInet converter RS485 Ethernet power supply passive PoE or 9 32V communication indication on the serial line galvanic separation RS485 ETH installation on the DIN rail 2 modules Terminals RJ15 for RS485 1 www foxtron eu ...

Page 2: ...ecification bus RS485 Ethernet speed ETH 10 100M protocol ETH TCP IP supply voltage 9 32 V consumption 1 5 W 50 150 supply 32 9V mA consumption RS485 5 mA wires cross section 0 08 1 5 mm2 ingress protection degree IP20 galvanic separation RS485 ETH 4 kV ambient working temperature 25 60 C storage temperature 25 60 C weight 80 g Consumption depending on voltage supply 2 www foxtron eu ...

Page 3: ...Mbit it is on 100Mbit Tx Sending of the data on RS485 blinking signalizes outgoing data on the serial line Rx incoming communication on RS485 bus blinking signalizes incoming data to the serial line 3 www foxtron eu SERInet Rx Tx Serial Ethernet Converter ETH 100M ETH passive PoE 9 32V ...

Page 4: ... Consumption in both cases is 1 5W supply current is in both cases dependent on the connected voltage Passive PoE Power supply is distributed together with the Ethernet to the ETH connector Power supply is inserted in the data cable using the common passive PoE injector Supply voltage can be in range 9 32V IN 9 32VDC DC power supply 9 32V to the terminal IN 9 32VDC Serial line is galvanically sepa...

Page 5: ...e IP address of the converter In the factory settings the address is 192 168 1 241 If the address is unknown the converter can be found using DALIconfig program which is downloadable for free on the www foxtron eu Default Ethernet settings in show in the following picture 5 www foxtron eu ...

Page 6: ...ection Setting the parameter to 0 is this function switched off Allow new connection if the existing connection has been idle for this many seconds The inactive time after which is allowed to start new connection Setting the parameter to 0 is this function switched off TCP setup for outgoing connection Make outgoing connections Never SERInet converter does not create connections On power up SERIne...

Page 7: ...aracters 0 waits forever the time after which the received characters are sent 0 signs that the data will not be sent dependently on the time Flush TCP UDP frame when this character is received Enter NA to disable Decimal character value ASCII after which reception will be sent If the NA is input no character is selected For example CR carriage return is 13 By pressing the button Submit New Settin...

Page 8: ...r of data bits Data Parity None no parity used Odd used odd parity Even used even parity Stop Bits number of stop bits Password setup is shown in the following picture Password into the web configuration is not required by default For change of password fill the User Name and twice new password In the case that you do not want to use password leave the password fields blank By pressing the button ...

Page 9: ...X In the case of using with Power Express system PEX it is suitable to insert the reduction on the RJ15 connector which is used for PEX bus by default Recommended setup CUSTOM PACKETIZATION for PEX bus 9 www foxtron eu ...

Page 10: ...Dimensions in mm tel 420 274 772 527 e mail info foxtron cz web www foxtron eu 10 www foxtron eu 45 90 10 58 35 35 ...