MS600V2 Universal Multi-Spectral
Camera User's Manual
11
1)
PWM trigger mode also needs to set threshold time T, range 0<T
<20ms ,PWM
signal frequency range: 50 Hz-400Hz;
2) Confirm and save;
3) The external trigger function of the camera can be checked by
setting the external trigger source.
3.3.5
Cascade trigger
Cascade trigger is mainly used for synchronous shooting of 2 or
more multispectral cameras. The camera is divided into two parts,
master camera and slave cameras, The PWM_OUT pin of the main camera
is connected to the PWM_IN pin of the slave camera, See 6.2.1 camera
interface for details; The main camera sets the shooting mode
according to the normal process, slave cameras set to external
trigger mode (signal type: PWM, temporal threshold:1.5 ms).After the
setting is completed, the flight mission will be executed. The master
camera
will
trigger
all
the
slave
cameras
to
take
pictures
synchronously when shooting. The event interval between the master
and slave cameras is less than 1ms.
3.3.6
Manual exposure
Check the manual exposure option in each trigger mode, you can adjust the
exposure time and gain corresponding to each channel uniformly or
independently on the preview page. See 3.4.3 for details.
3.3.7
Advanced settings
The advanced settings menu includes image storage format, channel