GAIA 160AG-Agricultural Spraying Drone
User Manual
©
2020 FOXTECH All Rights Reserved
7
In the pop-up menu, select “Nozzle Model” (recommended to use the nozzles listed in the menu, otherwise
the calibration may be biased), then click “Start Calibration”, the aircraft will automatically spray until the App
prompt to enter the liquid pump L calibration.
((2)(liquid pump L calibration
Accurately measure 1 - 5 L of water using a measuring cup and add it to the pesticide tank.
Enter the amount of water in the pesticide tank on the App. It is important to ensure that the actual amount
of water is the same as the input value, otherwise the calibration will be biased. Click “Start Calibration” and
the aircraft will automatically spray to the App to enter the liquid pump R calibration.
((3)(liquid pump R calibration
Same as the liquid pump L calibration procedure. App prompt Pump R calibration is complete, wait for a
while until the App prompts “Flow Calibration Complete” and the entire calibration process is complete.
3. Perform the steps to remove the duct air again and then start the normal spray operation.
During the calibration process, click > to cancel the calibration. The flow accuracy is the data before
this calibration.
Need to recalibrate
1. Replace the nozzles of different models. Note: After replacing the nozzle, you need to select the
corresponding nozzle in the App option. Enter the operation interface, click > to select the nozzle
model.
2. Replace the liquid with different consistency.
3. After the first task is completed, the error between the actual working area and the theoretical working
area is more than 15%.