4. Switch on the equipment using the switch (0/1) that is located at the bottom of the equipment
body.
a) Once the power supply is ON, the temperature lamp will be lit on level 4 and “0” will be
shown on the display.
b) If “[ ]” is shown on the digital time display once the power supply is ON, this means that
the rotary cover is not closed correctly and the equipment cannot operate correctly.
c) Once the power supply is ON, the equipment should become warm within 4 minutes; if
not, the audible alarm will sound to indicate that there is no water in the added water conta-
iner and you need to add some more water.
d) Choose the operation mode and press START.
5. Working mode selection:
a) Working mode selection depends on the customer’s needs; there are 5 care modes
available.
b) If the customer requires adjustment of the operation time, you can press the time prolon-
gation key to change the time.
c) If the customer requires adjustment of the working temperature, press the temperature
level adjustment key “-” once to lower the temperature by one level or press the temperature
level adjustment key “+” once to increase the temperature by one level.
d) Each working program switches infrared on by default. When the equipment starts wor-
king, the infrared lamp lights up inside the helmet but you can switch it off before or during
operation of the equipment.
e) The fan and ozone functions can be activated only when the equipment is working.
6. Change of working mode before the start of operation:
Even if the equipment is not yet working but the working mode has already been chosen or
the operation time and temperature are already set, you must still press the Clear key before
you make changes.
7. During operation
a) During operation, the time digital display shows the remaining time and the decimal point
flashes once a second.
b) If lack of water occurs in the added water container during operation, the equipment will
stop heating. If the temperature in the helmet falls below 40
o
C, the audible alarm will sound.
c) If the rotary cover is raised during operation, the equipment will stop heating. The error “[ ]”
will be displayed. Close the cover and the equipment will resume operation.
d) During operation, when 3 minutes of operation are remaining, the digital time display
starts flashing.
8. Change of working mode during operation:
a) To change the working mode during operation, press the Clear key first. After the equip-
ment has stopped, choose the working mode once again.
b) You can change time and temperature during operation.
9. End of operation:
a) Once the operation is finished, the digital time display will show “0”, the electronic audible
alarm will sound and the equipment will stop spraying and moistening.
b) Po zakończeniu każdego trybu roboczego, prosimy o opróżnienie Pojemnika Wody