Owner’s Manual Page
Water and Waste Systems - Section J
Periodically.check.the.sump.pump.screen.for.clogs..
to.prevent.drainage.problems.from.occurring.in.the.
shower.drain..Refer.to.the.manufacturer’s.literature.
included.in.the.owner’s.packet.
J - 3 GREY WATER SYSTEM
The.grey.water.system.is.optional.on.Vista®.models...
The.water.from.the.galley.sink,.head.sink.and.shower.
will.drain.into.a.sump.and.is.pumped.into.a.grey.water.
holding.tank.respectively...The.waste.level.indicator.is.
located in the head compartment. A pumpout fitting
labeled.WASTE.but.designated.for.grey.water.is.
provided.on.the.deck..Refer.to.the.drawings.at.the.
end.of.this.section..
NOTICE
Certain geographical areas have restrictions
on grey water being pumped or drained
overboard. Be sure to check all local, state
and federal laws in the boating area.
J - 4 SHORE WATER CONNECTION
Shore.water.connection.is.standard.on.the.318.Vista
®
.
models..This.feature.allows.the.direct.connection.of..
a.city.or.shoreside.water.supply.to.the.boat’s.water.
system.to.provide.a.constant.supply.of.fresh.water.
without the need to constantly refill the water supply
tank..This.minimizes.pressure.pump.operation.thus.
extending.the.life.span.of.the.pump.
Dockside.shore.water.pressure.can.vary.dramatically...
Excess.pressure.could.damage.the.boat’s.water.
system.so.the.shore.connection.also.regulates.the.
water.pressure.to.a.maximum.of.35.psi..
The shore water inlet/regulator fitting is located
outboard,.on.the.starboard.side.of.the.transom.above.
the.swim.platform,.inside.the.transom.washdown.
storage.area..See.Figures.J-3.and.the.drawings.at.the.
end.of.this.section.
To.use.shore.water,.connect.a.hose.from.the.shore.
water faucet to the shore water fitting on the boat and
turn.on.the.shore.water..The.water.system.of.the.boat.
will.then.be.pressurized.by.city.water.if.the.system.
was.previously.primed.
On.the.318.Vista
®
.models.the.water.heater.incorpo-
rates.a.heat.exchanger..The.heat.exchanger.allows.
the.engine.coolant.to.heat.a.portion.of.the.fresh.water.
supply.while.the.engines.are.operating..This.option.
will.provide.hot.water.at.times.when.120.volt.power.is.
not.available..Additional.information.on.heat.exchang-
ers.is.covered.in.the.engine.and.hot.water.heater.
manufacturers’.manuals..Please.refer.to.Section.H..
on.Electrical.Systems.for.additional.information..
D. Using The Shower
Turn.on.the.faucets.to.desired.temperature,.remove.
the.shower.spout.from.its.holder,.move.the.diverter.
lever.on.the.shower.head,.and.the.shower.is..
operational.
When.using.the.shower,.draw.the.shower.curtain.
before using the shower. Damage to the finish can
result if surrounding walls and flooring are allowed to
become.excessively.wet..Thoroughly.dry.these.areas.
after.showering.
The water temperature can vary during shower
use as the pressure pump cycles on and off.
For greatest consistency, turn the cold water
on full, then mix in hot water until the desired
temperature is obtained.
A.shower.sump.pump.is.incorporated.into.the.drain.
system.of.the.shower..The.shower.drains.into.the.
sump.pump.located.forward.of.the.aft.cabin..The.
water.will.then.be.pumped.overboard..If.a.grey.water.
system.is.installed,.the.water.will.be.pumped.into.the.
grey.water.holding.tank.
The.sump.pump.includes.an.automatic.bilge.switch.
and.is.protected.by.a.circuit.breaker.at.the.AC/DC.
cabin.panel..The.sump.pump.will.automatically.start.
as.soon.as.the.water.in.the.sump.reaches.a.level.that.
will cause the float on the switch to rise.
After showering, let the water flow for a period of time
to flush the pump of soap residue. Check the sump
.
for.excess.residue..When.rinsed.out,.the.pump.will.
automatically.shut.off.
If water flow from the shower head appears to be
restricted,.it.may.be.due.to.sediment.accumulating.at.
the.shower.head..If.necessary,.remove.the.head.and.
clean the discharge holes with a fine wire.
Summary of Contents for 318 VISTA
Page 1: ...3 1 8 V I S T A O W N E R S M A N U A L 0 9 0 2 8 5 4...
Page 2: ......
Page 4: ......
Page 52: ...Owner s Manual Page 48 Warranty and Service Section...
Page 54: ...Owner s Manual Page 50 Warranty and Service Section...
Page 81: ...Owner s Manual Page 77 Electrical Systems Section FIGURE H 3 318V GENERATOR OPTION 2 0F 3...
Page 82: ...Owner s Manual Page 78 Electrical Systems Section FIGURE H 4 318V GENERATOR OPTION 3 0F 3...
Page 103: ...Owner s Manual Page 99 Water and Waste Systems Section FIGURE J 14 318V HEAD HARDWARE 1 OF 3...
Page 104: ...Owner s Manual Page 100 Water and Waste Systems Section FIGURE J 15 318V HEAD HARDWARE 2 OF 3...
Page 105: ...Owner s Manual Page 101 Water and Waste Systems Section FIGURE J 16 318V HEAD HARDWARE 3 OF 3...
Page 200: ...Electrical Schematics Owner s Manual Page 196 318 VISTA HELM BREAKER PANEL ASSEMBLY...
Page 206: ...Electrical Schematics Owner s Manual Page 202 318 VISTA DIESEL BATTERY SWITCH PANEL ASSEMBLY...
Page 215: ...Electrical Schematics Owner s Manual Page 211 318 VISTA AC DC PANEL ASSEMBLY 1 of 4...
Page 216: ...Electrical Schematics Owner s Manual Page 212 318 VISTA AC DC PANEL ASSEMBLY 2 of 4...
Page 217: ...Electrical Schematics Owner s Manual Page 213 318 VISTA AC DC PANEL ASSEMBLY 3 of 4...
Page 218: ...Electrical Schematics Owner s Manual Page 214 318 VISTA AC DC PANEL ASSEMBLY 4 of 4...
Page 219: ...Electrical Schematics Owner s Manual Page 215 318 VISTA CE AC DC PANEL ASSEMBLY 1 of 4 El...
Page 220: ...Electrical Schematics Owner s Manual Page 216 318 VISTA CE AC DC PANEL ASSEMBLY 2 of 4...
Page 221: ...Electrical Schematics Owner s Manual Page 217 318 VISTA CE AC DC PANEL ASSEMBLY 3 of 4...
Page 222: ...Electrical Schematics Owner s Manual Page 218 318 VISTA CE AC DC PANEL ASSEMBLY 4 of 4...
Page 235: ......
Page 236: ......