Recommendations for Maintenance

Chemical Maintenance:

It is very important that you maintain the correct level of chemicals in your spa. Otherwise, you 
run the risk of damaging the jets and the heating elements, as well as encouraging cloudy water 
and skin and eye irritations. Also remember that chemical damage is not covered under warranty. 

Please refer to Chemical Safety Instructions at the back of the manual for further instructions.

Cover:

 Clean the cover with soap and water once per month to remove things like tree sap and 

dirt.

Side Panels:

 Wash the side panels periodically with water. 

Spa Shell:

 When you change the water, wipe the shell down with Fast Orange or some other 

biodegradable cleaner and rinse the shell out and drain the water out or vacuum it out of the foot 
well.

Water:

 Replace the water 2 to 6 months based on your amount of use, personal preference, or 

dealer recommendations.

To drain your spa:

 Grab the handle on the cap with pliers and pull it straight out, then turn it 

about 1/4 turn to the left and then pull it out about 3”. This will lock the tube into place so you 
can remove the cap and not lose any water.  Then attach a water hose to the tube and push the 
tube in about half way and drain the water as needed.  After finishing, simply pull the tube back 
out 1 inch, remove the hose, install the cap and push the tube back in until it stops. Then twist the 
tube to the right and push it the rest of the way back in to hide away.

Filter:

 Clean the filter once a month by backwashing with garden hose or placing it in the 

dishwasher but do not allow it to go through the drying cycle of dishwasher. Replace the filter 
once a year. 

To remove your filter: 

Never try to remove your spa filter lid, basket or cartridge while spa 

pump is running.  Turn spa breaker off.  If you have a screw filter remove the floating weir tube 
and counter clock wise unscrew the filter and remove.  If you have a drop in filter turn the 
telescopic lid counter clock wise 

¼

 turn to remove, lift out the filter basket to remove filter.   

Reverse the process for installation. If your basket and lid will not lock, your filter cartridge is 
either not sitting in the housing properly or the basket is not sitting on the filter cartridge 
properly.

Summary of Contents for XL SWIM SPA SERIES

Page 1: ...Owner s Manual Copyright Four Winds Spas 2016 Specifications subject to change...

Page 2: ...d helpful tips on enjoying your new Four Winds Spa Also you can enter your spa s information in the Record of Ownership section on page 23 for quick reference in the future Also enclosed in this manua...

Page 3: ...Electrical Installation Instructions 12 13 Electrical Safety 14 Understanding Spa Controls and Features 15 Beginning Startup Procedures 15 16 Hot and Cold Weather Use 16 17 Troubleshooting 18 Recomme...

Page 4: ...ectrical supply for this product must include a suitable rated switch or circuit breaker to open all ungrounded supply conductors to comply with the National Electrical Codes The disconnection means m...

Page 5: ...purpose 14 DANGER RISK OF ELECTRICAL SHOCK Do not permit any electrical appliance such as a light telephone radio or television within 5 feet 1 5m of a spa 15 WARNING Water temperature in excess of 38...

Page 6: ...od pressure and circulation 27 Because occasional users of the spa may not be aware of all the potential risk associated with spa usage they should be made aware of these Important Safety Instructions...

Page 7: ...partment door open Self closing door provided B CAUTION Risk of Electric Shock Replace components only with identical components C WARNING Prevent Electrocution Do not connect any auxiliary components...

Page 8: ...d as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F 37 C The Symptoms of Hyperthermia Include Dizzine...

Page 9: ...make sure that the surface can offset at least 100 lbs 45 kg per square foot You dealer is not usually qualified to make judgments on weight bearing abilities of structures so always consult a qualif...

Page 10: ...seal around the conduit placed through the hole in the side panel All 120 Volt capable spas require a Dedicated 15 AMP GFCI service connection An optional 15 Amp GFCI 12ft cable is available from Four...

Page 11: ...02895224 3 All field installed metal components such as rails ladders drains or other similar hardware within 5 feet of the spa or hot tub shall be bonded to the equipment grounding bus with copper c...

Page 12: ...all of your connections are correct Generally if the breaker will not stay engaged it is a wiring problem with the neutral wire Note The neutral and the ground wires cannot touch anywhere in between t...

Page 13: ...13 EURO Wiring Specs 50 Hz 1 x 32 AMP Service for 1 3 Pump Spas 2x 32 AMP Service for 4 Pump Spas...

Page 14: ...he power of a pump between two sets of jets or a set of jets and a Master Massage jet or jets This is a very large valve Bullet Style Jet These jets offer a straight water stream and this type cannot...

Page 15: ...e Two pump EU spas will heat about 4 6 degrees per hour All of these times are approximate If your spa has a PR or Priming Mode code on the topside it will take 4 to 6 minutes for it to go into the re...

Page 16: ...cian check voltage at the spa control system It is easy to blow fuses when first wiring a new spa if you accidentally put the wires in the wrong place or touch anything powered in the spa control pack...

Page 17: ...nd August being it is the hottest part of the day To set your spa filtration time to filter between certain hours first be sure you are on proper cycle generally F2 or FIL2 then shut off the breaker t...

Page 18: ...the left and then pull it out about 3 This will lock the tube into place so you can remove the cap and not lose any water Then attach a water hose to the tube and push the tube in about half way and d...

Page 19: ...reset shut off the power to the spa and call your dealer or service organization OH Overheat The spa has shut down One of the sensors has detected that the spa water is 110 F at the heater DO NOT ENTE...

Page 20: ...rvice organization LF Persistent low flow problems Displays on the fifth occurrence of HL message within 24 hours Heater is shut down but other spa functions continue to run normally Follow action req...

Page 21: ...s to measure it Calcium hardness is sometimes called total hardness and is simply a measure of the minerals in your water including calcium and magnesium If you do not have enough hardness your spa wi...

Page 22: ...tion drain or filter lid or weir assembly This has been reported in persons who when submerging themselves underwater allowing hair to come close and or within the reach of the suction fittings suctio...

Page 23: ...s XL Swim Spa Record of Ownership Four Winds XL Swim Spa Record of Ownership Four Winds Model Serial Number Date Purchased Dealer Name Dealer Number Dealer Address Dealer City State Service Technician...

Reviews: