FOUR WINDS INTERNATIONAL
Following manual override operation, failure to return all valves to normal position may
result in one or more jack legs drifting down from their retracted (stowed) position.
For cartridge valves, rotate the center screw fully counter-clockwise. For directional valves,
rotate the red knob until it ‘snaps’ back to the normal position.
In the event of electrical failure, the jack leg(s) may be retracted manually by following the
procedure below.
1. The individual cartridge valves are clustered together on the side of the pump manifold.
(They are labeled 1 thru 4 on the diagram on the next page). Locate the screws on the
appropriate cartridge valve(s). Using a small flat blade screwdriver, turn the screw(s)
clockwise until all the way in*.
* NOTE:
The normal operating position of the screw in the cartridge valve is the counter-clockwise
‘out’ position. The only time the valve should be shifted manually is when attempting to operate
jack(s) via manual override.
2. Locate the red knurled knob on the directional valve** DV2. This valve will be on the
opposite side of the manifold from the cluster of cartridge valves. Pull the red knob out
and turn 1/4 turn. The knob will remain in the 'out' position.
** NOTE:
The normal operating position of the red knob on the directional valve(s) is the ‘in’
position. The only time the valve should be shifted manually is when attempting to operate jack(s)
via manual override.
3. To retract, locate the red knurled knob on the directional valve**DV1. This valve will be on
the adjacent side of the manifold to the cluster of cartridge valves. Pull the red knob out
and turn 1/4 turn. The knob will remain in the 'out' position.
4. Remove the black plastic cap from the top of the motor. Use a small flat head
screwdriver. Place the drill with the 7/16" (11mm) hex bit on the manual override shaft
located at the top of the motor. Run drill in a clockwise direction at 2000 r.p.m. (minimum).
The jack leg(s) will retract.
5. When retraction is complete, return the cartridge valve(s) and the directional valves DV1
& DV2 to the normal positions. Reinstall black plastic cap on the motor.
Interior Controls & Operations
4-7
Emergency Retraction Procedure
Summary of Contents for Chateau
Page 1: ......
Page 13: ...FOUR WINDS INTERNATIONAL Limited Warranty 6...
Page 19: ...FOUR WINDS INTERNATIONAL General Information 1 4...
Page 113: ...FOUR WINDS INTERNATIONAL Water Systems 8 14...
Page 123: ...FOUR WINDS INTERNATIONAL Propane Gas Systems 9 10...
Page 141: ...FOUR WINDS INTERNATIONAL Care Maintenance 10 18...
Page 146: ......