F8X14 Series User Manual
2: Output
◆
Analog quantity work mode
The IP MODEM has 2 analog quantity ports in all, IO4, IO5. These ports are corresponding with
pin 11, pin 12. IP MODEM will gather the data of the analog quantity port as the MODBUS
commond when the analog quantity work mode is One-time colletion and the Modbus work mode
is Network RTU.
AT Command:
AT+ADCMODEn=x
n = 1/2
1: IO4 (Pin11)
2: IO5 (Pin12)
x = 0/1
0: Disable
1:One-time colletion
3.5.8 SMS Setting
◆
SMS Sending Number
If the network connection fail, IP MODEM will send the data which come from serial port
As the content of the messages to the SMS Sending number. (This function is called SMS backup