background image

                                                         

                             

User Manual                                                                                                                       

 

Xiamen Four-Faith Communication Technology Co.,Ltd.

 

                         

Page 33 of 42 

     

Add

   

J1-J3,3

rd

Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China

                                                                       

http

//www.fourfaith.com      Tel

  +86 592-6300326    6300325    6300324          Fax

+86 592-5912735

 

 

 

 

AT Command: 

 

AT+EXCALx=OM,<date>,<strTime>,<holdTime> 

          <date>: 0-31 

          <strTime>:      Format "12:30:00" 

          <holdTime>:    Hold time value(Unit:Second) 

 

For example: 

  IP Modem power on at 09:00:00 on the 28th every month,and power off 1 hour later. 

           

AT+EXCAL3=OM,28,"09:00:00",3600 

 

7.Power on with time interval 

 

 

Summary of Contents for F2114

Page 1: ...odel Model Product Type F2114 GPRS IP MODEM F2214 CDMA IP MODEM F2314 EDGE IP MODEM F2414 WCDMA IP MODEM F2514 TD SCDMA IP MODEM F2614 EVDO IP MODEM Xiamen Four Faith Communication Technology Co Ltd Add J1 J3 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China Zip Code 361008 Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 http www fourfaith com ...

Page 2: ...nication Technology Co Ltd Page 2 of 42 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Files Revised Record Date Version Remark Author ...

Page 3: ...y Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Four Fait...

Page 4: ... Xiamen Four Faith Communication Technology Co Ltd Page 4 of 42 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 ...

Page 5: ...4 Specifications 8 Chapter 2 Installation Introduction 11 2 1 General 11 2 2 Encasement List 11 2 3 Installation and Cable Connection 11 2 4 Power 14 2 5 Indicator Lights Introduction 14 Chapter 3 Configuration 15 3 1 Configuration Connection 15 3 2 Configuration Introduction 15 3 3 Run the configure Tool IP Modem Configure exe 16 3 4 Re power IP MODEM 17 3 5 Configuration 17 3 5 1 Data Service Ce...

Page 6: ...on could be 1ower than 1mA 12VDC It has compatible digital I O channel ADC input pulse counter and pulse wave output function It has been widely used on M2M fields such as intelligent transportation smart grid industrial automation telemetry finance POS water supply environment protection post weather and so on 1 2 Features and Benefits Design for Industrial Application High powered industrial cel...

Page 7: ...or remote management Support several work modes Convenient configuration and maintenance interface High performance Support TCP server and support multi TCP client connection optional Support double data centers one main and another backup Supply 5 I O channels compatible 2 pulse wave output channels 2 analog inputs and one pulse input counters Support multi data centers and it can support 5 data ...

Page 8: ...nal 450MHz optional 153 6Kbps 30dBm 104 dBm F2314 EDGE IP MODEM GSM850 900 1800 1900MHz GPRS EDGE Class 12 236 8Kbps GSM850 900 33dBm GSM1800 1900 30dBm 106 dBm F2414 WCDMA HSDPA HSUPA IP MODEM UMTS WCDMA HSDPA HSUPA 850 1900 2100MHz 850 900 1900 2100MHz optional GSM850 900 1800 1900MHz GPRS EDGE CLASS 12 HSUPA 5 76Mbps Upload speed HSDPA 7 2Mbps Download speed UMTS 384Kbps DL UL 24dBm 109 dBm F25...

Page 9: ...Indicator Power ACT Online Antenna Cellular Standard SMA female interface 50 ohm GPS Standard SMA female interface 50 ohm lighting protection optional SIM UIM Standard 3V 1 8V user card interface 15KV ESD protection Power Terminal block interface reverse voltage and overvoltage protection Power Input Item Content Standard Power DC 12V 0 5A Power Range DC 5 35V Power Consumption Working States Powe...

Page 10: ... SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Weight 210g Environmental Limits Item Content Operating Temperature 25 65º C 13 149 Extended Operating Temperature 30 75º C 22 167 Storage Temperature 40 85º C 40 185 Operating Humidity 95 Non condensing ...

Page 11: ...Installation Introduction 2 1 General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 Cellular Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 Table 2 1 Encasement List 2 3 Installation a...

Page 12: ...side and insert card sheath back to the SIM UIM card outlet Warning Forbid to install SIM UIM card when powered Installation of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced User Interface Signal Definition Pin Number Signal Name Default Function Extensib...

Page 13: ...e pulse wave input counter ADC and pulse output Installation of cable F2X14 adopts industrial terminal block interface The recommendatory cable is 28 16AWG The detail description of standard layout adapter and communication cables as is following Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarity Black White Alternate Anode Black Cathode RS232 Cable Cable Color Corresponding DB9 M ...

Page 14: ... 0 5A power adaptor 2 5 Indicator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator Light State Introduction Power ON IP MODEM is powered on OFF IP MODEM is powered off ACT BLINK Data is communicating OFF No data Online ON IP MODEM has logged on network OFF IP MODEM hasn t logged on network Communication Interface RS232 Communication Interface RS485 F2X14 ...

Page 15: ...ction There are two ways to configure the IP MODEM Configuration software tool All the settings are configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure st...

Page 16: ...al Parameters column shows the current serial port settings To configure IP MODEM please choose the correct serial port which connects to IP MODEM and the baud rate is 115200 with no parity then open the serial port If the button text is Close it shows the serial port now has been opened If the text is Open you should open the port first When the port opened the Output Info column will display Por...

Page 17: ...t configure columns It s now ready to configure 3 5 Configuration 3 5 1 Data Service Center Settings Settings on this page are the parameters related to Data Service Center DSC Data Center Number IP MODEM support two Data Service Center methods to transmit data Main and Backup IP MODEM always tries to connect with the Main DSC If fails to connect with Main DSC it will connect with Backup DSC at on...

Page 18: ...overned Setting details please reference the section 3 5 5 AT command AT SVRCNT x x Data Service Center number Note every AT command is terminated with a enter character Main Center Addr Port IP Address and Port of the Main DSC It s better to set the port greater than 1024 AT command of the Main DSC IP address or domain name AT IPAD xxx xxx The IP address or domain name AT command of the Main DSC ...

Page 19: ...domain name AT Command of the 2 5 DSC port AT PORTn xxx n is 1 4 correspond to port of center 2 5 xxx The port value Example Set IP address of center 3 as 166 111 8 238 and port 5001 the AT command is as following AT IPAD2 166 111 8 238 AT PORT2 5001 Main and Backup Center DNS Server When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When t...

Page 20: ...acket with TCP protocol Data transmission with TCP protocol heartbeat packet and application data transmission are in the same TCP connection TRNS IP MODEM work as a common GPRS MODEM It can be used in SMS CSD Dial up applications TTRN Heartbeat packet with UDP protocol Data transmission with TCP protocol TLNT IP MODEM work as a telnet client LONG Heartbeat packet with UDP protocol Data transmissi...

Page 21: ...ake IP MODEM online AUTO IP MODEM always keeps online SMSD send a special short message to make IP MODEM online CTRL make IP MODEM online through a phone call to IP MODEM DATA send special serial data to make IP MODEM online MIXD the combination of SMSD CTRL DATA IP MODEM will be online when meet one of these three trigger methods AT Command AT ACTI xxxx xxxx one of the above trigger methods Debug...

Page 22: ... Command AT SERMODE xxx xxx one of the above serial mode Communication Baudrate 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 bps 38400 38400 bps 56000 56000 bps 57600 57600 bps 115200 115200 bps AT Command AT IPR xxx xxx one of the above baudrate Auto Back To Main Server 0 No 1 Yes This item is only valid when you set Data ...

Page 23: ...ETMAIN x x 0 or 1 Device ID The identity number of IP MODEM the value should be 8 bytes hex decimal characters AT Command AT IDNT aabbccdd aabbccdd the identity number of IP MODEM SIM Card No The phone number of the SIM card AT Command AT PHON xxxxxxxxxx xxxxxxxxxxx the SIM card phone number Bytes Interval The time interval used to determine whether the serial data frame transmission has completed...

Page 24: ... valid when the WorkMode is TCST It s the self defined heartbeat string It can be empty the maximum length is 70 bytes AT Command AT LINKRGST xxx xxx self defined heartbeat string Connect Retry Times Reconnect Time Interval In normal applications IP MODEM will always try to connect with the center even if the center has problems or closed To reduce these unnecessary wireless data flow you can conf...

Page 25: ...only valid when the WorkMode is PROT If this item is set to 0 IP MODEM will transfer meaning to 0xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the PROT work mode If this item is set to 1 all the transmission is transparent AT Command AT STRAIGHT x x 0 or 1 3 5 3 Other Settings Network APN access point name Username username to login the I...

Page 26: ...777 AT Command of APN AT APN xxxx xxxx access point name AT Command of Username AT USERNAME xxx xxx username AT Command of Password AT PASSWORD xxx xxx password AT Command of Call Center AT CENT xxx xxx call center phone number of ISP SMS Center Your local SMS center number AT Command AT SMSC xxx xxx your local SMS center number Heartbeat Interval Time interval sent heartbeat packet unit is second...

Page 27: ...r Password This item is valid only when the Trigger Type is SMSD or MIXD IP MODEM will keeps in idle state until it receives the trigger short message Then it will connect to the center AT Command AT SMSDPSWD xxx xxx SMS content to trigger IP MODEM online Data Trigger Password This item is valid only when the Trigger Type is DATA or MIXD IP MODEM will keeps in idle state until it receives the trig...

Page 28: ...rval This item is valid only when the Data Center Number is greater than 1 When one of the configured data center lost connection IP MODEM will try to reconnect after the configured reconnect interval AT Command AT MCONTIME xxx xxx reconnect time interval unit is second 3 5 4 Scheduled Power ON OFF Setting RTC Real Time Clock Time Setting Click to ensure the setting AT Command AT EXCCLK yyyy mm dd...

Page 29: ...options value1 value2 value3 Options D Disabled Scheduled Power On Off function is disabled Default O On Set the IP Modem power on time S Shut Down Set the IP Modem power off time Setting type IP use for power on C use for power off T Time Set the action time point H per Hour Set a time point of every hour D per Day Set a time point of every day W per Week Set a time point of every week M per Mont...

Page 30: ...0324 Fax 86 592 5912735 AT Command AT EXCALx D Note There is no blank in this AT command the same as followings 2 On time switch power on AT Command AT EXCALx OT strLongTime holdTime strLongTime Format 2010 08 01 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 12 30 00 and power off at 13 30 00 on August 1st 2010 AT EXCAL5 OT 2010 08 01 12 30 00 3600 3 Power on per h...

Page 31: ...th com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx OH strTime holdTime strTime Format 00 30 00 holdTime Hold time value Unit Second For example IP Modem power on at the 30th minute in every hour and power off 10 minutes later AT EXCAL1 OH 00 30 00 600 4 Power on per day AT Command AT EXCALx OD strTime holdTime strTime Format 12 30 00 ...

Page 32: ...r On at 09 00 00 everyday and power off 1 hour later AT EXCAL3 OD 09 00 00 3600 5 Power on per week AT Command AT EXCALx OW week strTime holdTime week 0123456 replace to Sunday Monday Tuesday Wednesday Thursday Friday and Sunday ordinal strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on every Wednesday and Friday and power off 1 hour later AT ...

Page 33: ...a http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx OM date strTime holdTime date 0 31 strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on the 28th every month and power off 1 hour later AT EXCAL3 OM 28 09 00 00 3600 7 Power on with time interval ...

Page 34: ...t Minute holdTime Hold time value Unit Second For example IP Modem power on interval every 10 minutes and power off 120 seconds later AT EXCAL1 OP 10 120 8 IP Modem online offline with time interval AT Command AT EXCALx OP intervalTime holdTime intervalTime interval time value Unit Minute holdTime Hold time value Unit Second For example IP Modem online interval every 10 minute and offline 120 seco...

Page 35: ...e 35 of 42 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx ST strTime 10 Power off per hour AT Command AT EXCALx SH strTime 11 Power off per day ...

Page 36: ... J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx SD strTime 12 Power off at the same time in every week AT Command AT EXCALx SW week strTime 13 Power off per month ...

Page 37: ...a http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx SM date strTime 14 Power off with countdown AT Command AT EXCALx SC afterTime afterTime Countdown value Unit Second For example IP Modem power off 600 seconds later AT EXCAL1 SC 60 Note If the aftertime is 0 the IP Modem will power off immediately ...

Page 38: ... the output information Version Display Show the software and hardware version Signal Value Display current wireless signal value Factory setting Restore to factory settings Show Config Show current IP MODEM settings Show Baudrate Display the communication baudrate Auto Detect Simple way to determine whether IP MODEM work fine Save Output Save the output info to a file Save Config Save the current...

Page 39: ...35 Restore Config Restore settings from a previous saved configure file 3 7 Work State Switch This tool can work in two states Config and Communication Config This state is used to configure parameters of IP MODEM Communication This state is used as a common serial communication tool Reboot Device Enter Communication State This function button is used to reboot IP MODEM and make the software switc...

Page 40: ...325 6300324 Fax 86 592 5912735 Appendix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 ...

Page 41: ...361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Data bits 8 Parity None Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key continuously until IP MODEM enter configure state as following ...

Page 42: ... Ltd Page 42 of 42 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 7 IP MODEM has entered configure state you can configure the parameters through AT command ...

Reviews: