background image

F2X14-D IP Modem User manual

Page 3 of 31

Xiamen Four-Faith Smart Power Technology Co.,Ltd

.

Add

Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen.China

Hotline

400-8838-199

Tel

0592-6300320

Fax

0592-5912735

https://en.four-faith.net/

Copyright Notice

All contents in the files are protected by copyright law, and all copyrights are reserved

by Xiamen Four-Faith Communication Technology Co., Ltd. Without written permission, all
commercial use of the files from Four-Faith are forbidden, such as copy, distribute,
reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual
(all files shall be not revised, and the copyright and other proprietorship notice shall be
reserved) are welcome.

Trademark Notice

Four-Faith

、 四 信 、

are all registered trademarks of

Xiamen Four-Faith Communication Technology Co., Ltd., illegal use of the name of Four-
Faith, trademarks and other marks of Four-Faith is forbidden, unless written permission is
authorized in advance.

Summary of Contents for F2 14-D Series

Page 1: ...llowing model Model Product Type F2114 D GPRS IP MODEM F2414 D WCDMA IP MODEM F2614 D EVDO IP MODEM F2814 D FDD LTE IP MODEM Note D means use in power industry Xiamen Four Faith SmartPowerTechnology Co Ltd Hotline 400 8838 199 Tel 86 592 6300320 Fax 86 592 5912735 Web https en four faith net Add 11th Floor A 06 Area No 370 Chengyi Street Jimei Xiamen Fujian China ...

Page 2: ... Fax 0592 5912735 https en four faith net Files Revised Record Date Version Remark Author 2015 5 26 V1 0 0 Initial version ZBQ YJH 2016 4 1 V1 0 1 Add F2414 D and F2614 D ZBQ ZQZ 2016 5 10 V1 0 2 Modify the product appearance diagram and parameter of supply voltage range Faine 2017 9 23 V2 0 0 Update the address and add 4G function Faine 2020 4 9 V2 0 0 Contents translation and layout Zoe ...

Page 3: ...logy Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四 信 are all registered trademarks of Xiamen Four ...

Page 4: ...nology Co Ltd Add Floor 11 Area A06 No 370 chengyi street Jimei Xiamen China Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net Product appearance Note Different types of accessories and interfaces may be different please refer to the actual product ...

Page 5: ...n and Cable Connection 11 2 4 Power introduction 13 2 5 Indicator 13 Chapter 3 Configuration 19 3 1 Interface specification 19 3 2 Configuration options 21 3 2 1 Local serial port Settings 21 3 2 2 Local serial port 2 Settings 21 3 2 3 DTU Working mode Setting 22 3 2 4 GPRS dial parameter setting 22 3 2 5 Support platform related Settings 22 3 2 6 Enterprise gateway related Settings 23 3 2 7 Multi...

Page 6: ...ed UDP frame format 25 3 3 Read Write configuration 20 3 4 Modification configuration 21 Chapter 4 Use Description 22 4 1 Working mode description 22 4 1 1 DC mode 22 4 2 Connection mode description 22 4 2 1 Long connection mode 22 4 2 2 Short connection mode 23 4 3 Check system and connection status 23 4 4 Remote upgarde 25 4 5 Local serial upgrade 25 Charpter 5 Test 27 5 1 DC Test 27 5 1 1 DCUDP...

Page 7: ...a cellular network allowing you to connect to your existing serial devices with only basic configuration It also has low power consumption states It has been widely used on M2M fields such as intelligent substation intelligent distribution network smart electricity meters intelligent interactive terminal intelligent scheduling intelligent home appliances intelligent electricity building power grid...

Page 8: ...tral management software to facilitate the management of equipment optional Support a variety of working modes which make it easy and flexible to use Convenient configuration and maintenance interface Support serial update remote maintenance can export the serial log Easy installation fast fixing conveniently and quickly High performance Support TCP server and support 4 TCP client connection optio...

Page 9: ...Mbps Download speed UMTS 384Kbps DL UL HSPA 21Mbps Download speed 5 76Mbps Upload speed TX power 24dBm RX sensitivity 109dBm F2614 D EVDO IP MODEM Standard and Band CDMA2000 1X EVDO Rev A 800MHz 800 1900MHz Optional 450MHz IS 95 A B a n d CDMA2000 1xRTT wirelessnetwork Bandwidth EVDO Rev A Download speed 3 1Mbps Upload speed 1 8Mbps EVDO Rev B Download speed 14 7Mbps Upload speed 5 4Mbps TX power ...

Page 10: ...ngle row of female header Stop bits 1 2 Parity none even odd Baud rate 300 115200bps Antenna IPEX connector 50 ohm SIM UIM Standard clamshell socket interface support 1 8V 3V SIM UIM card 15KV ESD protection Indicator Power SIM card Operation network state Power supply Item Content Standard power DC 12V 0 5A Power range DC 5 36V Consumption Item Content Communication 45 90mA 12VDC Standby 10 15mA ...

Page 11: ... when you unpack so that they can be used for future transportation IP MODEM include below components IP MODEM host 1 pcs According to customer s order User manual 1 pcs Rod antenna 1 pcs IPEX connector 11CM connection line one end is connected to DB9M and one end is 2 54mm pitch 5PIN with public row seat 1 pcs Standard Note The antenna may have been assembled to the host during packaging please c...

Page 12: ...P MODEM antenna interface is for IPEX connector Buckle the IPEX male head of the antenna to the antenna interface of IP MODEM and make sure that the connection is good so as not to affect the signal quality When the SIM card is installed or removed follow the icon on the device that indicate the direction of installation make sure the SIM card s metal interface is facing down so that it is in full...

Page 13: ...xtended serial port 2 of F2X14 D for receiving RS485_A 7 TXD2 Extended serial port 2 of F2X14 D for sending RS485_B 8 GND For signal 2 4 Power introduction IP MODEM usually apply to complex external environments In order to adapt to the complex application environment and improve the stability of the system IP MODEM adopts advanced power technology It can use DC 5 36V to power IP MODEM directly Wh...

Page 14: ...ion Power Network SIM Card Operation 1 ON X Flash alternately Module is on and at AT mode 2 ON X OFF Flash slowly Initialize the module by AT command 3 ON Flash quickly OFF Flash slowly Dialing 4 ON X Flash slowly OFF Waiting for activation short connection mode 5 ON X Flash alternately System dialing is successful the module is in data mode but the centers are not connected 6 ON X Flash in the sa...

Page 15: ... power on after chosing right serial configuration parameters the serial port can be used for system parameter configuration Note The configuration page can be entered with baudrates of 115200 and 8N1 in the first 3 seconds after booting Open configuration tool F2x14d_Soft15031718 exe showing as below Open the configuration tool after chosing right serial port parameter checking the hardware first...

Page 16: ...e current PC these serial ports are listed in the select serial port Please be patient when you click this item because it is slow to automatically identify the currently available serial port please select the serial port that was connected to F2X14 D and chose right parameter which be used Check the auto option configuration software can automatically detect the parameters that match the communi...

Page 17: ...ion is described below 3 2 1 Local serial port Settings Serial port baud rate 1200 2400 4800 9600 14400 19200 38400 57600 115200 bps Option 115200 Default Serial port data bits 8 Serial port stop bits 1 1 5 2 Option Serial port parity bits None odd Even Local serial port scan interval 100 ms 10 Default Packet response timeout seconds 5 Default Local serial port frame size bytes 1024 Default set op...

Page 18: ...ctivated Timing activation interval minutes According to this time the timer starts when entering the sleep mode and when the time is up the network will be reconnected to realize the timing activation function Range 0 1440 Timing offline interval minutes According to this time the network will be unblocked and restarted value is 0 means the time is infinite Generally fill in 0 range 0 60 Whether ...

Page 19: ...ay Need to fill in IP address port number and domain name of center if IP and domain name are filled in at the same time IP shall prevail Enterprise gateway connection mode TCP UDP DCTCP DCUDP Option Maximum number of retransmission allowed for transmission failure 0 TCP protocol retransmission utomatically Enterprise gateway heartbeat interval minutes Time interval of heartbeat pack range 1 60 DN...

Page 20: ...or No Chose Yes you can see the run logs through the serial port tool This parameter takes effect immediately upon completion of configuration 3 2 10 Related settings of network management platform Serial No A king of number that the gateway platform can identify the device 15 bit string Factory defined can not be modified Working mode Only SMS mode SMS plus IP mode or disabled List of trust Numbe...

Page 21: ...ter HEX type use HEX character UDP login frame For the enterprise gateway connection mode is pure UDP UDP login response frame For the enterprise gateway connection mode is pure UDP UDP heartbeat frame For the enterprise gateway connection mode is pure UDP UDP heartbeat response frame For the enterprise gateway connection mode is pure UDP UDP drop out frame For the enterprise gateway connection mo...

Page 22: ... at this point you can view the parameter configuration of the item If read successfully Parameter loading successfully will be displayed in the log contents information bar showing as below Similarly the download configuration also needs hardware detection is normal and log in as an administrator after the user has set the parameters click Download configuration if this step is successful Downloa...

Page 23: ...configuration modify the corresponding configuration parameters and then write configuration to modify the required parameters Or you can export and save the configuration information on the first write to the configuration When you need to modify the configuration enter the save file then modify the corresponding configuration parameters and then write the configuration There is a default configu...

Page 24: ...bottom device and the data center can be realized Function As a communication bridge between the bottom equipment and the data center Such as RTU PLC etc the data sent by the bottom device to the serial port is encapsulated into network packets and sent to the data center and he data from the data center can also be sent to the bottom device through the serial port 4 1 Working mode description 4 1...

Page 25: ... In this connection mode at least one of the three activation modes must be on In this connection mode users can control when to connect and when to disconnect For example set Timing off line interval 55 Timing activate interval 600 Phone activation open Local data activation close after networking it will automatically log off and enter the waiting activation state after 5 minutes without data tr...

Page 26: ...ate 2 ON X OFF Flash slowly Initialize the module by AT command 3 ON Flash quickly OFF Flash slowly Dialing 4 ON X Flash slowly OFF Waiting for activation short connection mode 5 ON X Flash alternately System dialing is successful the module is in data mode but the centers are not connected 6 ON X Flash in the same time APP is normal MP is normal WMMP is normal Note 1 ON means LED always bright ho...

Page 27: ...de when it is 1 represents an upgrade of the BOOT program b Upgrade mode 0 is TCP connection 1 is UDPconnection cc Number of window Value 1 16 The larger the value the faster the upgrade so TCP is recommended to be 16 UDP is recommended to be 4 The UDP mechanism causes the larger the value the slower it is ip The IP address of the software which is to be upgraded port The server port number of the...

Page 28: ...street Jimei Xiamen China Page 26 of 31 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net 2 Power F2X14 D now it will start upgrading showing as below 3 When the upgrade is complete the red box showing as below will be displayed in the interface 4 Close download tool restart the device ...

Page 29: ...ns before your test 1 A computer with Internet access run the test software F2X14D_DC exe on this computer in order to listen for a certain TCP UDP port for communication 2 Use RS232 serial port line to connect the device to the computer 3 A SIM card that has already open data service 5 1 DC Test 5 1 1 DCUDP mode Open F2X14D_DC exe showing as below Working mode must be configurated to DCUDP Connec...

Page 30: ...utton to stop listening on the port If you want to open it again click Control Start service button to start listening on the port 3 When the device connect to data center successfully local device number login time corresponding IP information will list in the window showing as below 4 You can test communication with data center now Data that data center received will show up in infomation window...

Page 31: ... data will send to data center Showing as below Data can be sent to the specified port through the center software Select the device number you want to send from the list local device number will be displayed in the corresponding window at the bottom and input data in the bottom of the right window click Send button data will be send out by software showing as below Data sent by the center to the ...

Page 32: ... Xiamen China Page 30 of 31 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net 5 1 2 DCTCP mode test Open test tool F2X14D_DC exe click TCP to enter TCP mode F2X14D_DC exe will work on TCP mode at this moment you can start test if you config the device to DCTCO mode Test steps is similar to UDP mode ...

Page 33: ...he remote server Solution 1 Check parameter of F2X14 D is right or not 2 Check SIMcard is insert correctly or not make sure the SIM card is not stopped Can be tested by dialing the card number 3 If the remote data server is within the LAN check that firewall port mapping Settings are correct or not Question 4 Unable to transmit data to field control equipment when connect to server data manager So...