Drainage

 

 

  Cockpit compartment : 

Hand pump 
Open  and  unfold  the  manual  pump  located  on  the  back 
trunk of the cockpit. 
Pipe stored inside the back locker of the cockpit. 
 
 
 
 

  

 

 
 

  Engine compartment: 

Electrical bilge pump 
Switch  on  the  function  at  the  electrical  distribution 
panel.Switch off from the end. 
3 possible positions :  -On 
 

 

-Off 

 

-Temporary 


 

  Hull : 

Electrical bilge pump 
Switch  on  the  function  at  the  electrical  distribution 
panel.Switch off from the end. 
3 possible positions  : -On 
 

 

-Off 

 

                            - Temporary  

 

 

 

Summary of Contents for SUMMERLAND 40 LC

Page 1: ......

Page 2: ...or Page 11 Setting the anchor Page 11 Raising the anchor Page 12 E On arrival in port Page 14 CONFORT A Electrical installations Page 15 B The refrigeration system Page 17 C Gas system Page 18 D Water...

Page 3: ...that the bilges are free of water Close all hull portlights and deck hatches Fill the water tanks from the plug situated in front of the bridge diesel tanks from the plugs situated on the back port a...

Page 4: ...safety equipment horseshoe buoys life raft Check for the absence of fuel and gas vapors inside the boat Switch on remote controlled battery circuit breakers switches at the entrance to the saloon or...

Page 5: ...cooling is opened Start the engine See B for a detailed description of the starting procedure Check that cooling water is discharged from the exhaust and the anti siphon thru hull skin fitting In cas...

Page 6: ...t speedo log GPS VHF according to the option installed In strong winds carefully chock or lash down anything that might move Check that the navigation lights are working before a night passage Inside...

Page 7: ...DAD MDP 026 003_a not contractual document 7 31 B Moteurs VOLVO D3 150CV with EVC electronic command system...

Page 8: ...DAD MDP 026 003_a not contractual document 8 31...

Page 9: ...DAD MDP 026 003_a not contractual document 9 31 1 Starting the engine...

Page 10: ...DAD MDP 026 003_a not contractual document 10 31...

Page 11: ...DAD MDP 026 003_a not contractual document 11 31 Caution Do not turn the starter motor for more than ten seconds Possible exhaust water backflow may damage the engine...

Page 12: ...DAD MDP 026 003_a not contractual document 12 31 2 Stopping...

Page 13: ...DAD MDP 026 003_a not contractual document 13 31...

Page 14: ...ease the engine speed steadily to allow engine temperature to rise Wide open throttle and cruising engine revs will vary according to the engines on board See engine instruction book These engine spee...

Page 15: ...DAD MDP 026 003_a not contractual document 15 31 D Mouillage Check that the port engine is running Check that the circuit breaker windlass is switched on aft port compartment Circuit breaker windlass...

Page 16: ...DAD MDP 026 003_a not contractual document 16 31 The command is made by the remote control of ascent and descent chain locker Command situation...

Page 17: ...tual document 17 31 Setting the anchor Unhook the safety tackle lower the anchor and the chain to the last few metres of the final desired length Attach onto the chain the snap shackle from the bridle...

Page 18: ...length of chain desired until the tension of the mooring gear has been taken up by the bridle ce que la tension du mouillage soit reprise par la patte d oie Raising the anchor Raise the anchor as far...

Page 19: ...DAD MDP 026 003_a not contractual document 19 31 Raise the anchor slowly making sure that the anchor is put into the anchor roller correctly...

Page 20: ...d for that use Caution When running keep clear of the windlass and the chain In particular pay a big attention on the protection of hands and feet If the load on the windlass is too great the circuit...

Page 21: ...ping procedure Switch off all electrical installations Close all gas supply valves on tank and appliances Check that the bilges are free of water Switch off the battery switches during extended stops...

Page 22: ...DAD MDP 026 003_a not contractual document 22 31 CONFORT A Electrical installations 1 Circuit 12V...

Page 23: ...system optional Connect the shore power cord by unwinding it completely or start the generator set Regularly check the state of the cable If the cable is damaged to replace it by an identical cable Ca...

Page 24: ...changeover switch to the right position Check the presence of the current thank to the light on the differential earth leak circuit breaker Switch on the differential earth leak circuit breaker and th...

Page 25: ...ion system 12 V Refrigerator Check the state of load of the park battery service on the voltmeter of the electrical panel The start up is done via the thermostat Set the refrigerators thermostat to th...

Page 26: ...e regulator stop valve fixed directly on the tank Open the main stop valve and the stop valve of the appliance to be used galley locker Each gas appliance is equipped with a safety system To light it...

Page 27: ...ter system Open the tank valve Eau douce sous la trappe de plancher de la cabine arri re b bord Valve Check that the water heater supply valve port engine compartment is always opened Valve Switch on...

Page 28: ...t off with a valve 2 Use of toilet Check that the sea water supply and evacuation valves for toilet are opened Under the floor in front starboard side Place the toilet lever to the Water in position a...

Page 29: ...he operation at least twice 3 Use of holding tanks To store the black water in the holding tank close the discharge seacock Caution Never force the pump Storage capacity 45 litre Regularly empty the h...

Page 30: ...DAD MDP 026 003_a not contractual document 30 31 4 Discharge shower Open the discharge valve situated in the cupboard of each bathroom In bathroom...

Page 31: ...Pipe stored inside the back locker of the cockpit Engine compartment Electrical bilge pump Switch on the function at the electrical distribution panel Switch off from the end 3 possible positions On...

Reviews: